MT1450 / MT1460/MT1463 5" and 6" Random Orbital Palm Sanders

VACUUM CONVERSION KIT 

INSTRUCTIONS FOR 5 IN. AND 6 IN.

RANDOM ORBITAL SANDERS

The MT1456CVK and MT1456SGVK Matco Vacuum Conversion
Kits allow the NV (non-vacuum) machines to be converted to CV
(central vacuum) or SGV (self-generated vacuum) machines.

General Disassembly Instructions for converting 
“NV” Machines to “CV” (Central Vacuum) or 
“SGV” (Self Generating Vacuum) Machines 

1. For safe conversion, shut off the air supply and disconnect it 

from the tool.

2. Remove the (36) NV Pad with a (35) 24 mm Pad Wrench, then 

remove the (34) Non-Vac Shroud from the Sander Housing. 

General Assembly Instructions for 
“CV” Shroud Conversion

1. Install the (5) SuperVac™ Shroud onto the Sander Housing. 

Make sure the line up slots and tabs are engaged.

2. Slide the inlet end of the (1) SuperVac™ CV Swivel Exhaust 

Assembly into the exhaust port of the (5) SuperVac™ Shroud 
until it hits the stop on the SuperVac™ CV Swivel Exhaust 
Assembly. Make sure the key on the SuperVac™ CV Swivel 
Exhaust Assembly bracket is aligned and engaged with the 
keyway on the Sander Housing.

3. Secure the (1) SuperVac CV Swivel Exhaust Assembly to the 

Sander Housing using (2) M5 Flanged Nut, (3) M5 Flat Washer 
and the (4) M5 x 12 Screw (CAUTION: Do not over torque 
the screw).

4. Screw on the (6) new vacuum style Pad (not included, see 

available pads on page 8) on (33) Spindle.

5. Grasp the Female Swivel Fitting on the (1) CV Swivel Exhaust 

Assembly and turn the fitting to thread the male end of a 
standard 1 in. flexible Vacuum Hose into the Swivel until the 
Hose is tight.

MT1456CVK

CENTRAL VACUUM CONVERSION KIT

Item

Part #

Description

Qty

1

RS145601

ROS SuperVac™ CV Swivel Exhaust Assm.

1

2

RS145602

Nut

1

3

RS145603

Washer

1

4

RS145604

Screw

1

5

RS145605

5/6 in. SuperVac Shroud

1

6

NA

Pad (not included)

NA

Additional Disassembly Instructions for Converting
“NV” Machines to “SGV” Machines 

1. Unscrew the Muffler Housing with a 21mm hex allen wrench. 

Take off the Bronze Muffler that is pressed into the Muffler 
Housing and set it aside for reuse later. The Muffler Housing 
and soft “foam-like” Muffler that are located in its cavity are 
not used for SGV Machines, but keep them in a safe place if 
the machine might be switched back to a Non-Vacuum 
Machine later.

CENTRAL VACUUM KIT

Pads not included.

WARNING:

5 in. pads must only be
used on 5 in. machines and
6 in. pads must only be
used on 6 in. machines.

Summary of Contents for MT1450

Page 1: ... work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are specially designed to filter out microscopic particles MT1450 MT1460 MT1463 Air Pressure 90 PSI 6 2 Bar 90 PSI 6 2 Bar 90 PSI 6 2 Bar Air Consumption 16 SCFM 16 SCFM 16 SCFM Pad Size 5 6 6 Maximum Speed 12 000 RPM 12 000 RPM 12 000 RPM Weight 1 6...

Page 2: ...o your hands and arms Discontinue use of tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming use Air under pressure can cause severe injury Never direct air at yourself or others Always turn off the air supply drain hose of air pressure and detach tool from air supply before installing removing or adjusting any accessory on this tool or before performing any main...

Page 3: ... s life because of faster wear and may create a hazardous condition Water in the air line will cause damage to the tool Drain the air tank daily Clean the air inlet filter screen on at least a weekly schedule The recommended hook up procedure can be viewed in Figure 2 The air inlet Figure 1 used for connecting air supply has standard 1 4 NPT American Thread Line pressure should be increased to com...

Page 4: ...6 RS47514 O RING 1 17 RS145017 ROTOR 1 18 RS47515A ROTOR BLADE 5 19 RS47520 KEY 1 20 RS145020 FRONT END PLATE 1 21 RS227B25 BEARING 1 22 RS47523 O RING 1 23 RS47524 LOCK RING 1 24 RS145024 5 5 in 3 16 in 5 mm ORBIT AirSHIELD SHAFT BALANCER 1 RS145024 6 6 in 3 16 in 5 mm ORBIT AirSHIELD SHAFT BALANCER 1 RS145024 61 6 in 3 32 in 2 5 mm ORBIT AirSHIELD SHAFT BALANCER 1 25 RS145025 FILTER 1 26 RS14502...

Page 5: ...MT1450 MT1460 MT1463 5 Rev 12 01 03 MT1450 MT1460 MT1463 5 and 6 Random Orbital Palm Sanders ...

Page 6: ...e Sander Housing 3 Secure the 1 SuperVac CV Swivel Exhaust Assembly to the Sander Housing using 2 M5 Flanged Nut 3 M5 Flat Washer and the 4 M5 x 12 Screw CAUTION Do not over torque the screw 4 Screw on the 6 new vacuum style Pad not included see available pads on page 8 on 33 Spindle 5 Grasp the Female Swivel Fitting on the 1 CV Swivel Exhaust Assembly and turn the fitting to thread the male end o...

Page 7: ...xhaust Assembly and turn the fitting to thread the male end of the 1 Vacuum Hose into the Swivel Fitting until the hose is tight 8 Place a small amount of a non permanent pipe thread sealant to the threads of the male end of the 1 4 Air Line fitting on the 1 Vacuum Hose Assembly and thread into the inlet port of the Sander Housing Use an 18mm wrench to hold the inlet port Bushing and torque the Ai...

Page 8: ... precise construction are the ideal complements to the performance of the Matco MT Series Random Orbital Sanders PART DESCRIPTION MT1450VP 5 in Tapered edge NV vinyl face MT1450HP 5 in Tapered edge NV hook face MT1450VHP 5 in Tapered edge vac hook face MT1450VAP 5 in Low profile screen vac J hook pad PART DESCRIPTION MT1460VP 6 in Tapered edge NV vinyl face MT1460HP 6 in Tapered edge NV hook face ...

Reviews: