POWER MANAGEMENT SYSTEM 

AND TOOL  OPERATION

This tool includes a power management system that allows the operator 

to adjust the amount of output power in the clockwise direction (forward). 

There is no power management system present in the counter-clockwise 

direction (reverse). To adjust the power output in the forward direction

turn the dial left or right to the desired power setting. Power output is 

indicated by enla

rging black swoosh on back housing. Lowest power 

setting indicated by thin swoosh area with highest power setting being 

thickest swoosh area.
The Power management system is only for reference and does not act 

as specific power settings. This tool includes a tip valve variable speed 

trigger design that further allows the operator to reduce the power 

output.
This tool is an impacting tool and not a torque meter. When specific 

torque is required, it must be checked with a torque meter after fitting the 

fastener with the Impact.

If a fastener does not move within five seconds, use a larger size Impact. 

Do not use Impact Wrench beyond rated capacity, as this can drastically 

reduce the tool life.

Always turn off the air supply, drain hose of air pressure and detach 

tool from air supply before installing, removing or adjusting any part or 

accessory on this tool, or before performing any maintenance on this 

tool.
NOTE: 

 Actual torque on a fastener is directly related to joint hardness, 

tool speed, condition of socket and the time the tool is allowed to impact.
Use the simplest possible tool-to-socket hook up. Every connection 

absorbs energy and reduces power.

NOTE:  During operation, safety goggles must always be worn to guard 

against flying debris (users and bystanders). 

MT2748 3/8" IMPACT WRENCH

FIG. 1

FIG. 2

Drain Daily

Regulator

Oiler

Quick Coupler

Leader

Hose

 

Nipple

 Do Not Install

Quick Coupling

Here

 

 

Nipple

 

Filter

 

Air Supply

 

Whip Hose

AIR INLET

TRIGGER

AIR SUPPLY

Tools operate on a wide range of air pressures. It is recommended 

that air pressure measures 90 psig at the tool with the trigger fully 

depressed and no load applied to the tool. Higher pressure (over 90 

psig; 6.2 bar) raises performance beyond the rated capacity of the tool, 

which will shorten tool life and could cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water in the air 

line will cause damage to the tool. Drain the water from air lines and 

compressor prior to running tool. Clean the air inlet filter screen weekly. 

The recommended hookup procedure can be viewed in the below 

figure.
The air inlet used for connecting air supply has standard 1/4" NPT. Line 

pressure should be increased to compensate for unusually long air 

hoses (over 25 feet). Minimum hose diameter should be 3/8" I.D. and 

fittings should have the same inside dimensions and be tightly secured.

Ensure an accessible emergency shut off valve has been installed in the 

air supply line and make others aware of its location.

TROUBLESHOOTING

Other factors outside the tool may cause loss of power or erratic 

action. Reduced compressor output, excessive drain on the air line, 

moisture or restrictions in air pipes or the use of hose connections of 

improper size or poor conditions may reduce air supply. Grit or gum 

deposits in the tool may cut power and may be corrected by cleaning 

the air strainer and flushing out the tool with gum solvent oil or an equal 

mixture of SAE #10 and kerosene. If outside conditions are in order, 

disconnect tool from hose and take tool to your nearest authorized 

service center.

LUBRICATION & MAINTENANCE

Lubricate the air motor daily with high quality air tool oil. If no air line 

oiler is used, run 1/2 oz. of oil through the tool. The oil can be squirted 

into the tool air inlet or into the hose at the nearest connection to the 

air supply, then run the tool. A rust inhibitive oil is acceptable for air 

tools.

 After an air tool has been lubricated, oil will discharge through the 

exhaust port during the first few seconds of operation. The exhaust port 

must be covered with a towel before applying air pressure to prevent 

serious injury.

WARNING

WARNING

FORWARD/REVERSE BUTTON

Summary of Contents for MT2748

Page 1: ...s those dust masks that are specially designed to filter out microscopic particles MT2748 Free Speed 8 800 RPM Breakaway Torque 600 ft lbs Maximum Torque 370 ft lbs Air Inlet 1 4 NPT Average Air Consu...

Page 2: ...uncomfortable positions over extended periods of time may be harmful to your hands and arms Discontinue use of tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming u...

Page 3: ...f air pressures It is recommended that air pressure measures 90 psig at the tool with the trigger fully depressed and no load applied to the tool Higher pressure over 90 psig 6 2 bar raises performanc...

Page 4: ...2320 Right Forward Button 1 208 RS12321 Left Reverse Button 1 301 RS12322 Bearing 1 302 RS12338 Cylinder 1 303 RS12324 Rotor 1 304 RS12325 Rotor Blade each 7 305 RS12326 Rear End Plate 1 Item Part No...

Page 5: ...manship the tool will be repaired free of charge and returned to you freight prepaid This warranty gives you specific rights You may also have other rights which vary from state to state The foregoing...

Page 6: ...caras anti polvo los que son espec ficamente dise ados para filtrar las part culas microsc picas MT2748 Velocidad Libre M xima 8 800 RPM Torsi n M xima 600 libras pie Torsi n de Operaci n 370 libras p...

Page 7: ...mente molestias estremecimiento o dolor Antes de continuar us ndola solicite el consejo m dico Resbalarse tropezarse y o caerse durante la operaci n de herramientas neum ticas puede ser una causa mayo...

Page 8: ...ADEADMINISTRACI NDEPOTENCIA Y OPERACI N DE LA HERRAMIENTA Esta herramienta incluye un sistema de administraci n de potencia que le permite al operador ajustar la cantidad de potencia de salida en el s...

Page 9: ...r defectuosa en cuesti n material o mano de obra durante el per odo de dicha garant a Para que se repare su herramienta devuelva la herramienta a cualquiera de los Centros de Garant a Autorizados de M...

Page 10: ...um cristallin provenant des briques du ciment et d autres produits de ma onnerie et Arsenic et chrome provenant du bois trait chimiquement Le risque que pr sentent ces expositions varient selon le nom...

Page 11: ...fortables sur des p riodes de temps prolong es peuvent tre nocifs pour les mains et les bras Discontinuez l usage de l outil si vous avez une sensation d inconfort de douleur ou des fourmillements Veu...

Page 12: ...ersonnes proximit MT2748 CL PERCUSSION DE 3 8 PO ALIMENTATION EN AIR Cet outil peut fonctionner l int rieur d une large plage de pression d air Il est recommand que la pression soit de 90 psi lorsque...

Page 13: ...ente un d faut de mat riau ou de main d uvre durant la p riode de garantie Pour faire r parer l outil retournez le l un des centres de garantie autoris s de Matco indiqu s ci dessous port pay Joignez...