DOC:  FPC-30040-CON
VER 1.0

TO RESET FAULT, PRESS MUTE BUTTON FOR 3 SECONDS

AN ACKNOWLEDGEMENT BEEP WILL SOUND WHEN FAULTS ARE CLEARED 

WARNING: HIGH VOLTAGE

ALL ELECTRICAL CONNECTIONS MUST BE CARRIED OUT

BY A SUITABLY QUALIFIED ELECTRICIAN

ACCESS BY AUTHORISED PERSONNEL ONLY

TO RESET FAULT, PRESS MUTE BUTTON FOR 3 SECONDS

AN ACKNOWLEDGEMENT BEEP WILL SOUND WHEN FAULTS ARE CLEARED 

WARNING: HIGH VOLTAGE

ALL ELECTRICAL CONNECTIONS MUST BE CARRIED OUT

BY A SUITABLY QUALIFIED ELECTRICIAN

ACCESS BY AUTHORISED PERSONNEL ONLY

INDICATOR LIGHTS GUIDE

WIRING CONNECTION DETAIL

FPC-30040-CON

ON STEADY

A pump fault/overload has occured

FLASHING

A prime loss fault has occured

ON STEADY

Pump is switched on to run

A high level alarm has been present for the preset time

FLASHING

A low level alarm is present

MOMENTARY PRESS

To mute audible buzzer

PRESS FOR 3 SECS

To reset alarms and faults

PRESS CONTINUOUS

To test indicator lights,

strobe and siren

MUTE/

RESET

PUMP ON

LEVEL ALARM 

FAULT

INDICATOR LIGHTS GUIDE

ON STEADY

A pump fault/overload has occured

FLASHING

A prime loss fault has occured

ON STEADY

Pump is switched on to run

ON STEADY

A high level alarm has been present for the preset time

FLASHING

A low level alarm is present

MOMENTARY PRESS

To mute audible buzzer

PRESS FOR 3 SECS

To reset alarms and faults

PRESS CONTINUOUS

To test indicator lights,

strobe and siren

MUTE/

RESET

PUMP ON

LEVEL ALARM 

FAULT

BMS

  Volt/Free

Fault

Common

PUMP 1

PU

M

P 1

 Ea

rt

h

PU

M

P 2

 Ea

rt

h

PUMP 2

PUMP 2

PUMP 1

PROBES

Low/Voltage

E5 E1 E2 E3

COMMON

STOP

START

HIGH

Probe Holder

s/s Probe rodes 

BRIDGE

IF NOT

REQUIRED

Thermal Switch 

12Vdc

T1 T2 T1 T2

PUMP 1 PUMP 2

P1

P2

P3

P1

P2

P3

SUPPLY

415Vac

E A1 A2

N

415Vac

MAINS POWER

SUPPLY

A3

Mounting

Frame/

Wall

INSTALLATION

MOUNTING

1. Controller enclosure must be   

    mounted in a vertical position.

2. Ensure mounting method does 

    not compromise enclosure

    weather proof rating.

3. Ensure access to main isolator is 

    not restricted.

4. Ensure cables/conduits entering 

    the panel have mechanical

    protection and that the

    penetrations are sealed and do   

    not compromise the weather 

    proof rating of the enclosure.

Note: 

Controller  must  be  earthed  and  all  electrical  connections  must  be  carried  out  by  a  suitably  qualified

Electrician. For Single Working Level Float Switch Applications, connect to “Start (Input 3)” terminals only, and NO 

bridge wire is required in “Stop (Input 2)” terminals.

CONNECTION

PUMP ON
FAULT

PUMP ON
FAULT

MAIN ISOLATOR

240Vac

MAINS POWER

SUPPLY

SUPPLY

PROBES

240Vac CONNECTIONS

E

A

N

E1

COM

MO

N

E1

St

op

E2

St

art

E3

High

Low/Voltage

C

onductivit

y

Probe

Connections

COMMON

FAULT

Volt/Free

BMS

PU

M

P

1

Ea

rt

h

PUMP 1

A

N

PU

M

P

2

Ea

rt

h

PUMP 2

A

N

PUMP 2

PUMP 1

Summary of Contents for FPC-30020-CON

Page 1: ...PUMP ON FAULT PUMP ON FAULT MAIN ISOLATOR P U M P C O N T R O L OWNER S OPERATION MANUAL Dual Pump Controller Installation and Operating Instructions MODEL FPC 30020 CON VER 1 0...

Page 2: ...st be Circuit Breaker Protected Qualified Electrician to determine appropriate amp rating Electrical connection to the panel must be carried out in accordance with Connection Instructions see page 3 A...

Page 3: ...not compromise the weather proof rating of the enclosure Note Controller must be earthed and all electrical connections must be carried out by a suitably qualified Electrician For Single Working Level...

Page 4: ...minute delay On High Level Alarm can only be reset manually High Level Alarm has 5 minute delay Mode A Standard Configuration Start Stop High Level operation When the Pump Start input is closed conta...

Page 5: ...n Input 1 contact closure the pump will not start delay start for 1 second and will not stop minimum run time for 10 seconds or 11 seconds from close of Input contacts This run on occurs even if Lead...

Page 6: ...Mode Timeout With DIP Switch 5 set to On the pump will only remain in Manual Mode for 5 minutes after which time it automatically reverts to Auto High Level Alarm Reset The controller will also use th...

Page 7: ...ction PUMP UP Function PUMP DOWN Sensitivity adjustable by a potentiometer 5 100k Measuring frequency 10Hz prevents polarization of liquid and raising oxidation of measuring probes Galvanically separa...

Page 8: ...tance Voltage n electrodes Current in probes Time response Max capacity of probe cable Time delay t Time delay after switching on t1 Accuracy Accuracy in setting mechanical Output Number of contacts C...

Page 9: ...se a tank made of a conductive material you can use it as probe C In case you require monitoring of one level only it is neccessary to connect inputs H and D and connect them to one probe in this case...

Page 10: ...10 CIRCUIT DIAGRAM...

Page 11: ...11 NOTES...

Page 12: ...level alarm is present ON STEADY Pump switched on to run ON STEADY A pump fault overload has occurred FLASHING A prime loss fault has occurred Silences the siren and if held down for 3 seconds clears...

Reviews: