10.- Fix the elements in their original position. Place the other two rows of bricks with the knobs face to face.
11.- Refit the inner front panel. If the bricks have been fitted correctly you will find no difficulty in refitting the panel (fig 4).
12.- Attach the front panel and fix it at the bottom edge with the two screws provided.
3.- USING THE STORAGE HEATER
The two controls at the top of the heater govern the input and output functions. Both are printed with the numbers 1 to 5.
The CARGA (CHARGE) control allows you to select the amount of heat you wish to store during the night.
During mild weather, it is normal to set your input control in a medium position. In cooler weather, the control could be set at 5 to give maximum
heat retention.
The stored heat will be delivered to the room by both radiant and convected methods. The convected heat can be regulated by using the output
control (DESCARGA) This control governs the continuous flow of convected heat from the outlet grill. Type AX-84 is completely automatic and
has no output control.
All heaters have an exclusive feature which makes it unnecessary to close the output control at night. The outlet grill will close automatically at
the beginning of the overnight charge.
4.- MAINTENANCE OF YOUR STORAGE HEATER
This storage heater does not require any special care. During the first few charges you may be aware of an unusual odour. This is normal and if
it happens, please ventilate the room until the odour disappears.
If dust accumulates on the heater surface it can be removed using a wet cloth when the heater is cold. Do not use solvents or abrasive products
for cleaning.
Mathius night storage heaters are manufactured under an assured quality system using environment friendly procedures.
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.
fig 5
fig 4