a
b
c
d
2mm
IN/OUTWARD
OPENING DOOR SEAL
(DOOR SHOWN IN OUTWARD
OPEN POSITION)
FIXED
PANEL
STAGE 5
DOOR
ADJUST
UNLOCK
IMPORTANT
LOCK
This stage is describing the Door adjustment.
a
.
Fit the door closure seal to the back of the door. The door closure seal can be adjusted away from the edge of the door to improve sealing
with the fixed panel or the fixed panel can be adjusted at the top to the seal.
Important. The inward/outward seal requires sufficient
compression to the fixed panel glass.
When initially opening the door both inwards and outwards the seal may deform unevenly and can
catch the fixed panel. Allow the seal to take a set in the closed position for 12 -24 hrs. Open the door inwards and outwards adjust as required
ensuring the seals works effectively for both directions of movement.
b.
Fit the magnetic closure panel seal to the edge of the closure panel. Check the polarity of the magnet is correct with the magnet on the
edge of the door. This seal can be adjusted away from the edge of the fixed panel to meet the door magnetic seal or the fixed panel can be
adjusted at the top to the door. Check there are no gaps between the door and magnetic closure panel seal.
c
.
To adjust the door left to right at the upper pivot point, loosen the socket cap screw in the top of the headrail by one turn only and adjust
the door as required.
d.
To adjust the door up and down at the lower pivot point, firstly loosen the locking screw in the lower pivot block. Then using the spanner
(supplied in the kit of parts) wind the nut at the base of the pivot block anti-clockwise to raise the door upwards.
Important - Re-tighten
locking screw
CLOSURE
PANEL
FIXED
PANEL