3mm
20mm
32mm REF
c
e
d
9mm
d
2mm REF
3mm
b
f
92 +/- 2.5mm
106 +/- 2.5mm
99 +/- 2.5mm
STAGE 8
WALL MOUNT
MIN.
ADJUSTMENT
WALL MOUNT
MAX.
ADJUSTMENT
WALL MOUNT
MID.
ADJUSTMENT
This stage is describing the temporary fitting of the top track to position the top track wall fixing.
a.
Before fitting the top track plumb the glass panels to check for vertical.
b.
Level a horizontal pencil line from the top of the Curved fixed panel wall mount. Mark a parallel line 9mm below the level line for the
centre reference of the top track wall fixing.
c.
Loosen the top track wall mount cap and top track wall fixing adjuster to allow for fitting the top track.
d.
Lower the top track into position, ensuring the top track glass clamps fit over the top edge of glass panels and the wall mount top
cap fits down the back of the wall mount at the top. Check the reference dimensions for the clamps to the edge of the glass panels.
e.
Adjust the top track wall fixing adjuster to the wall. Centre the cylindrical fixing plate on the 9mm reference line and mark around to
determine the fixing centre. Remove the top track and carefully set aside.
f.
The position of the wall fixing adjuster from the inside of the wall mount will vary depending on the adjustment/position of the glass
within the wall mount.