background image

 

Section 2. System Description 

Matrics develops and markets RFID solutions that are effective and affordable by offering a 
combination of low cost, long read range, and a very high read rate unmatched by other RFID 
systems. A Matrics RFID System gives you real-time, end-to-end visibility of products and assets in 
your factory, distribution center, retail outlet, or other facility. A typical Matrics RFID system 
consists of three main components:  

• 

Silicon-based

 RFID tags

 that can be attached to vehicles, trailers, containers, pallets, paper rolls, 

boxes, etc., to create a “people-free” wireless environment for tracking assets,  

• 

Reader network components

 (reader stations, readers, antennas, cables, connectors, power 

supplies, etc.) that power and communicate with the tags, and 

• 

The 

Matrics Visibility Manager (MVM)

 software that runs on your choice of host computer 

and collects tag data automatically. 

Product Description 

The 

Ruggedized Reader

 (PN: RDR-RUG-100) is an industrial strength UHF RFID Reader designed 

for the International Paper warehouse tracking system. The outer enclosure of the Ruggedized Reader 
is made of EMI/RFI watertight die-cast aluminum material, coated with a beige-colored, textured 
polyester powder paint. The enclosure meets standards (NEMA 4X, IP66, DIN 40050) for degree of 
protection, and is CSA certified (Type 4) for use with industrial control equipment. 

The Ruggedized Reader offers superior and robust read range capabilities, anti-collision features, and 
very high data read rates unmatched by other systems. It provides all of the RF and control functions 
required to power and communicate with Matrics passive RFID tags. It sends digital data to the tag 
(through one antenna at any given time) on a pulse width modulated On Off Keyed (OOK) 
transmitter signal, demodulates the identification signal received from the tag, and then sends the data 
to your host computer. 

The Matrics Reader network is structured to allow for flexibility in system configurations and in the 
arrangement of read points to optimize coverage at a low overall cost. Providing 12 physical antenna 
connections, the Ruggedized Reader allows up to 20 varying antenna combinations (depending on 
your application) attached directly to a single Reader. 

The Ruggedized Reader is designed for use in two different applications: 

• 

Clamp Truck – mounted on Taylor and/or Hyster clamp trucks, and 

• 

Reader Station – mounted overhead in a portal configuration. 

In the Clamp Truck application, the Ruggedized Reader is powered by a 48VDC power supply from 
Matrics mounted on the clamp truck, with on-board power filtering and regulation to accommodate 
gas and electric lift devices and associated noise/voltage variation. Refer to the 

Clamp Truck 

Application User’s Manual

 (DCN: MNI03H003) for more information about this application. 

2

 

Ruggedized Reader User’s Manual 

 

2003 Matrics, Inc.

 

Summary of Contents for RDR-RUG-100

Page 1: ...edized Reader User s Manual Revised October 6 2003 Document Control Number MNI03H001 Matrics Inc 8850 Stanford Boulevard Suite 3000 Columbia MD 21045 Tel 410 872 0300 Fax 410 872 0700 http www matrics...

Page 2: ...for identification purposes only and are the trademarks of their respective owners Statement of Rights IMPORTANT READ CAREFULLY Matrics products incorporate technology that is protected by U S patent...

Page 3: ...5 Ruggedized Reader Diagram Back View 6 LEDs 6 SECTION 4 INSTALLATION 7 Getting Started 7 Mount the Ruggedized Reader 7 Connect Antenna s to the Ruggedized Reader 8 Connect the Reader to a Host Compu...

Page 4: ...This page left intentionally blank iv Ruggedized Reader User s Manual 2003 Matrics Inc...

Page 5: ...n this User s Manual ACRONYM DEFINITION IC Integrated Circuit MVM Matrics Visibility Manager OOK On Off Keyed RFID Radio Frequency Identification TBD To Be Determined References For additional informa...

Page 6: ...or use with industrial control equipment The Ruggedized Reader offers superior and robust read range capabilities anti collision features and very high data read rates unmatched by other systems It pr...

Page 7: ...from Matrics PN RDR STA 100 Refer to the Reader Station User s Manual DCN MNI03H002 for more information about the Reader Station Refer to the Reader Station Application User s Manual DCN MNI03H004 f...

Page 8: ...UL approved compound against windblown dust and rain Vibration Withstands sinusoidal vibration to the following specifications o IEC 68 2 6 MIL STD 810E Method 514 4 o 10 55 Hz 0 15mm 03 91g o 55 500...

Page 9: ...Purpose I O Connector Two 2 Receive Antenna Connectors Front View 11 long includes connectors x 6 5 wide x 3 deep includes bridge Data Link LED Tag Read LED Error LED Bridge from Transmit Output to RF...

Page 10: ...Power LED Green LED is lit when the Reader is powered on and receiving power Data Link LED Green LED flashes as it communicates and indicates a good link Error LED Amber LED is lit to indicate a bad l...

Page 11: ...gedized Reader Before mounting the Ruggedized Reader you must select a location for it For best results consider the following when determining the optimal placement for your antennas and Ruggedized R...

Page 12: ...der Make sure that you unplug the power supply or power off the clamp truck to power off the system first before disconnecting cables Connect the Reader to a Host Computer The steps you must follow to...

Page 13: ...ately protected medical devices Consult a physician or the manufacturer of the medical device if you have any questions Other electronic equipment may also be subject to interference Radio Station Lic...

Page 14: ...rial Authorization RMA You must obtain a return material authorization RMA number from Matrics Customer Service refer to the Contact Us section in this User s Manual before you return any parts for re...

Page 15: ...eshooting In the event that you encounter a problem with your system refer to the following table for possible solutions PROBLEM POSSIBLE CAUSE SOLUTION TBD TBD TBD Ruggedized Reader User s Manual 200...

Page 16: ...Inc Section 8 Contact Us For sales service and technical assistance contact Matrics at Tel 410 872 0300 Monday Friday 8 30 a m 5 00 p m EST Fax 410 872 0700 http www matrics com Matrics Inc 8850 Stan...

Reviews: