MSC-CP59X59E Product Manual
Profile=1
SerBaud=115200
SerProto=Mascot
SysName=MSC-Panel
SysType=2
>
The example above shows a typical output of the Vars command for an MSC-GCP2U32 LCD panel.
3.10.47 W Command
Routers and MSC-GCP2U32 only
Write current matrix routing state to a preset. Recalling the preset later will restore the routing matrix to the
same state. This command modifies preset data which persists through power cycles.
Command
Description
W PRESET
Write current matrix routing state to PRESET.
Example to save state to preset 1
>W 1
>
3.10.48 WebPass Command
Assign a web password to password protect the web page interface. The serial and TCP/IP port Mascot protocol
control is not protected by this password. This value is stored and recalled on power up.
Command
Description
WebPass STR
Set web page password (blank to disable)
Examples of setting and clearing web page password
>WebPass SeCr3t
>WebPass “”
>
3.10.49 X Command
Routers and MSC-GCP2U32 only
Query or make changes to the matrix routing state. This command comes in several variations described by the
following table.
Command
Description
X
Query complete routing state (equivalent to S Command).
X DEST
Query connected sources for DEST for all levels.
Page 47 of 56
© 2013-2016 Matrix Switch Corporation