MSC-DE1664 Product Manual
all Destinations. This command stores preset information which is available through system power cycles.
Command
Description
PClr PRESET
Clear a preset.
Example to clear preset 1
>PClr 1
>
3.11.31 ProtoSer Command
Carina series only
NOTE:
Superseded by the
ctl.serial.proto
and
ctl.serial2.proto
.
Query or assign the serial protocol. The only available option is currently the case insensitive value "Mascot",
however additional control protocols may be added in the future. Value is stored and recalled on power up.
Command
Description
ProtoSer
Query the protocol used on the serial port.
ProtoSer PROTO
Assign the protocol used on the serial port (the only valid value is
currently "Mascot").
Examples
>ProtoSer
Mascot
>
3.11.32 PsetNames Command
Routers and MSC-GCP2U32 only
Query or assign preset names. Preset names are stored and recalled on power up.
Command
Description
PsetNames
Query all preset names.
PsetNames PRESET
Query a single preset name.
PsetNames PRESET, LABEL
Assign a preset label.
When querying names, labels are surrounded by double quotes and separated by newlines.
Examples
>PsetNames
“Startup”
“Preset1”
“Preset2”
Page 42 of 60
© 2013-2019 Matrix Switch Corporation