MSC-UTX62L Product Manual
>
The first 3 example commands are query commands. The last assigns an empty string to the second level of the
first source (thereby indicating that the first level label should be used).
3.11.43 SysName Command
NOTE:
Superseded by the
sys.name
Query or assign system name. The system name is provided for convenience when managing multiple Matrix
Switch Corporation systems. This value is stored and recalled on power up.
Command
Description
SysName
Query system name.
SysName STR
Set system name (up to 15 characters).
Example for querying and assigning system name
>SysName
MSC-Router
>SysName “MyRouter”
>
3.11.44 SysType Command
Protocol Version: 2.3
NOTE:
Superseded by the
sys.arch
.
Query the system series type, which is currently defined as one of the following values:
Value Series name
0
Carina
1
Lupus
2
Lynx
3
Hydra
4
Pyxis
NOTE:
This command was not added until version 2.3 of the Mascot protocol. On previous versions, this
command is available on the MSC-GCP2U32 LCD panel but not other Matrix Switch Corporation systems.
When determining the system type, if executing the command returns an Invalid Command error, the system
series can be assumed to be Carina.
Command
Description
SysType
Query the system hardware series.
Page 48 of 60
© 2013-2020 Matrix Switch Corporation