MSC-XD164L Product Manual

3

Hydra

4

Pyxis

NOTE:

 This command was not added until version 2.3 of the Mascot protocol.  On previous versions, this 

command is available on the MSC-GCP2U32 LCD panel but not other Matrix Switch Corporation systems.  
When determining the system type, if executing the command returns an Invalid Command error, the system 
series can be assumed to be Carina.

Command

Description

SysType

Query the system hardware series.

Examples

>SysType

E01: Invalid command

>SysType

2
>

The first example command shows the response that would be received on a Carina series system with older 
firmware not supporting the SysType command, the second example is what might be returned by an MSC-
GCP2U32 LCD panel.

3.11.45 Vars Command

Protocol Version: 2.3

Display all system configuration variables.  Useful in serial terminal or telnet sessions to view all configuration 
values.

Command

Description

Vars

Display all system configuration parameters.  Note that variables 
consisting of JSON data simply show the string JSON, to keep the 
output concise.  The output consists of one line per variable, with the 
variable name followed by an equals '='  and then the value (not 
quoted).

Examples

>Vars

DefaultProfile=1
DHCP=1

DNSPri=0.0.0.0
DNSSec=0.0.0.0

Firmware=1.5.1
Gateway=192.168.2.1

IP=192.168.2.80
Mac=00:00:00:00:00:00

MascotVer=2

Page 49 of 60

© 2013-2018 Matrix Switch Corporation

www.matrixswitch

 

 corp.com

 

 

Summary of Contents for MSC-XD164L

Page 1: ...ix Switch Corporation MSC XD164L Product Manual Compact 16 input 4 output 3G SDI Video Router with Button Control Panel Revision 1 8 Page 1 of 60 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 2: ...ALITY PERFORMANCE MERCHANTABILITY OR FITNESS FOR PURPOSE Matrix Switch Corporation disclaims all liability arising from this information and its use Use of Matrix Switch Corporation devices in life support and or safety applications is entirely at the buyer s risk and the buyer agrees to defend indemnify and hold harmless Matrix Switch Corporation from any and all damages claims suits or expenses ...

Page 3: ... commands and Panel GPIO commands Improved Software Update documentation Added pinouts for RS 232 and RS 485 serial port and GPIO Auxiliary interface Added XD series systems Revision 1 3 2016 05 17 Added MSC CP59X59E panel Revision 1 2 2015 08 20 Added protocol commands MtxGroup PanelDis and PanelExtEn Updated Mascot protocol information to version 2 4 New manuals for MSC V1616 LS DC MSC 1HD1616 L...

Page 4: ...2 2 Loading a preset 13 2 3 Presets Tab 13 2 3 1 Loading Work Matrix from a source target 14 2 3 2 Saving Work Matrix to a target 14 2 3 3 Usage scenarios 14 2 4 Labels Tab 14 2 5 Config Tab 15 2 5 1 System Settings 16 2 5 2 Network Settings 16 2 5 3 Button Panel Settings 17 2 6 Command Tab 18 3 Mascot Control Protocol 19 3 1 Protocol Changes 19 3 2 Telnet Access 20 3 3 Serial Access 20 3 4 Comman...

Page 5: ...mand 37 3 11 22 PairIO Command 37 3 11 23 PanelCmd Command 38 3 11 24 PanelCmdEn Command 39 3 11 25 PanelCond Command 39 3 11 26 PanelDis Command 40 3 11 27 PanelExtEn Command 41 3 11 28 PanelRate Command 41 3 11 29 PClr Command 42 3 11 30 ProtoSer Command 42 3 11 31 PsetNames Command 42 3 11 32 PSub Command 43 3 11 33 PView Command 43 3 11 34 Reboot Command 44 3 11 35 ReclkDis Command 44 3 11 36 ...

Page 6: ...e recovery procedure 52 4 3 TFTP Software 53 4 3 1 Windows 53 4 3 2 Mac OS X 54 4 3 3 Linux 54 5 Troubleshooting 56 5 1 Unknown IP address 56 5 2 Unexpected reboots 56 6 Reference 57 6 1 Specifications 57 6 2 Serial Interface Pinout 57 6 3 Glossary 58 7 Matrix Switch Corporation Warranty 60 Page 6 of 60 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 7: ...SDI signals will be auto re clocked for reduced jitter Other non standard rates between 125 Mbit s and 3 0 Gbit s will be passed through without re clocking or jitter reduction Adaptive cable equalization on each input can equalize input signals from Belden type 1694A cables up to lengths of 400m SD 140m HD and 120m 3G SDI BNC Video Outputs Connect SDI destinations to output connectors using 75 Oh...

Page 8: ...face for configuration and is also a convenient way to control the matrix routing of the device Devices come factory configured with default settings unless a pre configuration request is made during purchase an example being a multi device application 1 4 1 Accessing The Web Page Interface The default network IP address for this device is 192 168 2 60 Refer to the table below for the default IP a...

Page 9: ...els Labels can be assigned to video and audio if applicable sources and destinations Labels can also be assigned to presets Labels can be up to 8 characters in length The default source labels use Src as a prefix and the destination labels use Dest as a prefix example Src1 The presets are labeled Startup for Preset 0 and PresetN where N is a number from 1 to 9 for the remaining presets The Labels ...

Page 10: ... remote panels and computers need to be physically connected to the same LAN or allow IP packet routing between networks if on separate LANs SECURITY WARNING Matrix Switch Corporation devices are meant for installation in trusted LAN environments In the event that remote device configuration or control is desired over public networks or the Internet it is strongly recommended that some form of int...

Page 11: ...nations sources and or levels Example use scenarios Utilize an 8x1 remote panel to control a single destination of an 8x8 video router Use the local panel of a 16x16 two level Video and Audio router to control Video only and an additional 16x16 remote panel to control Audio independently Use a 4x4 panel to independently control 4 destinations of an 8x8 router and limit selectable sources to 4 sour...

Page 12: ...lines to aid in further description below The web page interface for other router systems is sized appropriately Remote Panels show only the Config and Command tabs Numbered sections in Figure 1 1 System name can be assigned on the Config tab 2 System firmware series and version 3 Tab navigation 4 Preset load drop down selection 5 Source connect buttons 6 Mute button may not be available on all sw...

Page 13: ...e Destination or a single level is selected 2 2 2 Loading a preset Presets store connection states for one or more Destinations Loading a Preset on the Routing tab consists of simply clicking on the Load preset drop down selector 4 in Figure 1 and selecting the desired preset which is then loaded and applied to the current routing matrix More information on Presets is contained in the following Pr...

Page 14: ...o a Preset will store the Work Matrix state to non volatile memory which persists through device power cycles and can be recalled at a later time 2 3 3 Usage scenarios The flexibility of the Presets Tab interface allows for several useful scenarios some of which are described below Batch connection operations To perform several connection operations all at the same time make the desired connection...

Page 15: ...umns for Video and Audio Sources and Destinations Single level routers will have a column for Source labels and one for Destination labels On multi level routers secondary levels can be left blank to use the same label as the first level Presets can also be assigned label names Click the Save button to save changes that have been made 2 5 Config Tab Page 15 of 60 2013 2018 Matrix Switch Corporatio...

Page 16: ...characters displayed at the top of the Web Page interface which is helpful when managing multiple systems Disable Reclockers Disable SDI reclockers not supported by all Routers 3D I O Pairing Enable pairing of destinations sources for two channel 3D support only supported by Routers with 2 or more destinations 2 5 2 Network Settings WARNING DHCP should only be enabled or the IPAddress or Netmask c...

Page 17: ...e panels control different levels of a Video Audio Router Control Mode Set the matrix control mode only present on Routers Available options include Local Button panel controls the router itself Remote Button panel controls a remote router at the IP address set by the Remote Router IP field Remote Sync Synchronize matrix crosspoint changes to another router at the IP address specified by the Remot...

Page 18: ...e Command text entry line followed by pressing the Enter key to execute them The results will be displayed in the text area below the command line Clicking the Clear Output button will clear all command output in the lower area See the section Mascot Control Protocol for more information Page 18 of 60 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 19: ... without modification using this protocol For information about other third party control system manufacturers who support MASCOT contact Matrix Switch Corporation 3 1 Protocol Changes As new commands are added or other changes occur the MASCOT protocol version is incremented The protocol revision can be obtained using the MascotVer command Protocol revision history Mascot version 3 0 Added System...

Page 20: ...nd prompt character 3 3 Serial Access Matrix Switch router systems come equipped with a serial port which can be used as another means of sending Mascot commands Connect a Computer system to the device using a 9 pin RS 232 serial cable Using this interface requires a serial terminal program such as HyperTerminal on Windows Configure the terminal software for 115200 bps 8N1 In addition Local Echo s...

Page 21: ...SCII 10 The Prompt A prompt character is displayed each time a command or chain of commands is entered to indicate readiness to receive additional commands If an error occurs in response to a command an error will be displayed prior to the prompt with the following format E00 Error message 00 will contain a 2 digit decimal error code Table 4 shows possible error codes which may be returned in resp...

Page 22: ...matically interpret argument as string spaces and commas not allowed Hex 0x3D 0xNN where NN are 2 hex digits from 0 9 A F or a f Double quoted One or more characters surrounded by double quotes An Argument Single quoted One or more characters surrounded by single quotes An Argument Table 5 Basic Argument Types Arguments are shown in the Help command output surrounded by square brackets Arg or pare...

Page 23: ...orted String String A generic string argument max length depends on the command Value A general value Value type depends on setting See System Parameters Table 6 Command Argument Types 3 7 System Parameters MASCOT protocol version 3 0 adds commands for setting and querying configuration and other system parameters These commands greatly simplify the MASCOT command set and supersede several configu...

Page 24: ...rial port baud rate in bits second ctl serial2 log Boolean RW AS RS 485 serial port protocol log enable ctl serial2 proto String RW AS RS 485 serial port protocol selection mascot svs etc mtx serial Number R Current matrix serial number incremented on every routing change mtx sync Boolean RW AS Keep current routing state stored to preset 0 Effectively retains last matrix routing state even after a...

Page 25: ...implementation and support variations between different system types Many of these commands have been superseded by System Parameters in Mascot protocol version 3 0 Command Arguments Description DHCP 0 1 DHCP enable FrameIP IP Remote router IP address the panel will control Gateway IP Network gateway IP address IP IP System IP address MAC MAC address MapDest Dest Dest Lvl Matrix destination remap ...

Page 26: ...ail Please note that command availability may vary between firmware series and versions Details of availability are documented for each command 3 11 1 C Command Routers and MSC GCP2U32 only NOTE Superseded by the MtxCfg Command The C command queries the matrix size The response is in the format Dests Srcs Levels Flags1 Flags2 Where Dests is the count of system destinations Srcs is the count of sou...

Page 27: ... assigned via the IP Netmask and Gateway commands A value of 1 enables DHCP and will obtain the values for the IP address Netmask and Gateway from your DHCP server This value is saved and recalled on power up WARNING A DHCP server must be present on your network for this to function properly Using DHCP allows for dynamic IP or fixed IP assignment from a central location the DHCP server Using this ...

Page 28: ...echo enable E 0 1 Set matrix echo enable 0 to disable 1 to enable Examples to query and then enable matrix echo E 0 E 1 3 11 5 Firmware Command NOTE Superseded by the sys firmware System Parameter Query the system firmware series and version Example Firmware Pyxis 1 1 7 3 11 6 FrameIP Command NOTE Superseded by the pnl ip System Parameter Query or assign the remote router IP address Usually only u...

Page 29: ...meter Table for a list of currently defined parameters This command supersedes many individual configuration commands NOTE This command queries Active values of parameters which may differ from values in Stored memory Values in Stored memory are loaded at system startup and can be queried with the GetS Command See System Parameters for more details Command Description Get Display all system parame...

Page 30: ...arameter identifier separated by an equals character and the value GetS Parameter Display the Stored value of a single parameter or a subset of parameters under a given parameter node 3 11 10 Help Command Display command reference information 3 11 11 IP Command NOTE Superseded by the net ip System Parameter Query or assign the system IP address This setting is saved and recalled on power up WARNIN...

Page 31: ...etection for outputs Format is one decimal number per output 0 Unlocked 1 SD 2 HD Example for a 16x4 system SD HD Unlocked Unlocked LockStatus 1 2 0 0 3 11 13 MAC Command NOTE Superseded by the net mac System Parameter Query system Ethernet MAC address Command Description MAC System Ethernet MAC address in hh hh hh hh hh hh where each hh is a pair of hex digits Example MAC 00 50 C2 8B DF FE 3 11 1...

Page 32: ...ination 2 on the second level The second example queries the mapping for a single destination The third example maps destination 1 to physical destination 5 on all levels The fourth example maps destination 1 to physical destination 6 on the second level only 3 11 15 MapSrc Command Routers only Protocol version 3 0 Query or assign matrix source mappings Source mappings provide a means to remap log...

Page 33: ...over what protocol version is in use The returned value is either an integer such as 2 or major and minor version numbers separated by a period such as 2 3 Example MascotVer 2 3 3 11 17 MtxCfg Command Routers and MSC GCP2U32 only Protocol Version 2 0 Query matrix configuration This command replaces the C command and provides the ability to query the matrix dimensions labels current matrix state an...

Page 34: ... or reclocker disable If an argument is specified 0 7 then a more descriptive JSON structure is returned of the following form newlines and spaces added as a visual aid but are not necessarily part of the response version 1 status STATUS levels name NAME type TYPE destCount DEST_COUNT srcCount SRC_COUNT flags FLAGS destNames NAME NAME srcNames NAME NAME state SRC SRC psetData SRC SRC psetNames NAM...

Page 35: ... to response as a visual aid MtxCfg7 version 1 status OK levels name Level1 type VIDEO destCount 4 srcCount 4 flags mute destNames Dest1 Dest2 Dest3 Dest4 srcNames Src1 Src2 Src3 Src4 state 1 2 3 4 psetData 1 2 3 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 psetNames Startup Preset1 Preset2 Preset3 Preset4 Preset5 Preset6 Preset7 Preset8 Preset9 The example output abov...

Page 36: ...assigning I O grouping MtxGroup 1 1 MtxGroup 2 4 MtxGroup 2 4 The first example MtxGroup command shows that I O grouping is disabled on both levels of a 2 level system The second command configures the system for dual I O grouping on level 1 and quad I O grouping on level 2 On an example 16x16 two level router this would result in an 8x8 matrix on level 1 and a 4x4 matrix on level 2 3 11 19 NetMas...

Page 37: ...preset information which is retained and available through system power cycles Command Description PAdd PRESET DEST SRC Add a connection of SRC to DEST on PRESET for all levels PAdd PRESET DEST SRC LEVEL Add a connection of SRC to DEST LEVEL on PRESET Example PAdd 1 2 3 PAdd 1 3 0 2 The first command adds a connection from Source 3 to Destination 2 in Preset 1 The second command Mutes Destination ...

Page 38: ...witch to ground Panel buttons and GPIO pins are specified by numeric ID Panel buttons are numbered beginning with ID number 1 Panel button order depends on the panel but generally has the top left button as button 1 followed by number 2 in the lower left corner number 3 in the top second column continuing to alternate between top and bottom rows till the last button lower right hand corner GPIO au...

Page 39: ...ns 0 disable 1 enable Examples for querying and enabling panel command conditions PanelCmdEn 0 PanelCmdEn 1 3 11 25 PanelCond Command Protocol Version 3 0 Query and assign panel button GPIO status and indicator conditions Panel button GPIO conditions are a counterpart to Panel Commands and provide a means to easily implement custom status to light panel buttons or change logic states on output GPI...

Page 40: ...he first example above queries the currently assigned panel GPIO conditions which shows that button number 1 and 2 have P0 and P1 conditions assigned respectively which lights the button LEDs when the current matrix routing matches preset 0 or preset 1 respectively and GPIO pin 3 GPIO pins start at 65 will output a logic 1 if the matrix matches preset 0 The second command queries the panel conditi...

Page 41: ... setting 0 disabled The second command enables the external panel interface 3 11 28 PanelRate Command Protocol Version 2 1 For changing remote button panel refresh rate When a button panel is configured to control a remote router the current connection status is refreshed at regular intervals This command can be used to increase or decrease the rate which is saved and recalled on system power up T...

Page 42: ...se insensitive value Mascot however additional control protocols may be added in the future Value is stored and recalled on power up Command Description ProtoSer Query the protocol used on the serial port ProtoSer PROTO Assign the protocol used on the serial port the only valid value is currently Mascot Examples ProtoSer Mascot 3 11 31 PsetNames Command Routers and MSC GCP2U32 only Query or assign...

Page 43: ...PRESET DEST Remove any existing connection to DEST in PRESET for any level PSub PRESET DEST LEVEL Remove any existing connection to DEST LEVEL in PRESET Example PSub 1 2 PSub 1 3 2 The first command removes any connection to Destination 2 in Preset 1 The second command removes any connection to Destination 3 Level 2 on Preset 1 3 11 33 PView Command Routers and MSC GCP2U32 only View presets Displa...

Page 44: ...ly Protocol Version 2 1 Command for disabling or enabling SDI reclockers Not all router systems support this option Value is saved and recalled on power up Command Description ReclkDis Query current value of reclocker disable ReclkDis 0 1 Enable or disable reclockers 0 or 1 respectively Examples ReclkDis 0 ReclkDis 1 The first command above queries the current reclocker disable value which returns...

Page 45: ...ery destination are shown This command without an argument is equivalent to the X Command with no arguments If an argument value of 1 is supplied then the matrix state is displayed with labels The state of each destination is displayed one per line in the format DestNLvl1 SrcLvl1 DestNLvl2 SrcLvl2 Example S1 Dest1 Src4 Dest1 Src4 Dest2 Src3 Dest2 Src3 Dest3 Src2 Dest3 Src2 Dest4 Src1 Dest4 Src4 Th...

Page 46: ...on the parameter and is defined in the System Parameter Table Values in Stored memory are loaded at system startup See System Parameters for more details Command Description Set List all parameter identifiers which can be set one per line Set Parameter Value Set a parameter s Active and or Stored value depends on parameter Examples of listing all writable parameters and setting the net ip paramete...

Page 47: ...will not take effect until the system is restarted NOTE Some parameters may not be assignable in Stored memory for example if it does not make sense to recall a value on start up See System Parameters for more details Command Description SetS List all parameter identifiers which can be set in Stored memory one per line SetS Parameter Value Set a parameter s Stored value 3 11 42 SrcNames Command Ro...

Page 48: ...TE Superseded by the sys name System Parameter Query or assign system name The system name is provided for convenience when managing multiple Matrix Switch Corporation systems This value is stored and recalled on power up Command Description SysName Query system name SysName STR Set system name up to 15 characters Example for querying and assigning system name SysName MSC Router SysName MyRouter 3...

Page 49: ...rmware not supporting the SysType command the second example is what might be returned by an MSC GCP2U32 LCD panel 3 11 45 Vars Command Protocol Version 2 3 Display all system configuration variables Useful in serial terminal or telnet sessions to view all configuration values Command Description Vars Display all system configuration parameters Note that variables consisting of JSON data simply sh...

Page 50: ...o PRESET Example to save state to preset 1 W 1 3 11 47 WebPass Command Assign a web password to password protect the web page interface The serial and TCP IP port Mascot protocol control is not protected by this password This value is stored and recalled on power up Command Description WebPass STR Set web page password blank to disable Examples of setting and clearing web page password WebPass SeC...

Page 51: ... a destination if supported for a given level Examples X 1 1 2 2 3 8 0 4 X 3 3 8 X 3 4 X 4 0 2 In the above examples the first command queries the matrix routing state typical of a 16x4 system for example the second command queries destination 3 only the third command connects source 4 to destination 3 on all levels and the fourth command mutes destination 4 level 2 Command stacking Command stacki...

Page 52: ... image has been transferred to the device s FLASH storage area 5 The device will automatically reboot to perform the remainder of the software update during which the web page interface may display a connection error which can be ignored 6 The software update may take an additional minute to complete and power should not be disconnected during this time 7 Reload the web page interface by holding d...

Page 53: ...to the IP address 192 168 2 59 Consult the TFTP Software section for details 4 3 TFTP Software There are many different options for TFTP client programs the choice of which depends on what operating system you are using on the computer being used to perform the TFTP transfer from The following sections list some options for various operating systems 4 3 1 Windows Windows XP has a TFTP client insta...

Page 54: ... put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer Make sure to perform the necessary actions to prepare the system for an update prior to attempting the transfer 8 The TFTP program will indicate if the transfer was successful or not 9 If the transfe...

Page 55: ... TFTP transfer binary put MSC Pyxis Firmware x x x img 6 Make sure to replace MSC Pyxis Firmware x x x img with the correct version number of the file 7 Pressing ENTER after the put command will initiate the TFTP transfer Make sure to perform the necessary actions to prepare the system for an update prior to attempting the transfer 8 The TFTP program will indicate if the transfer was successful or...

Page 56: ...unning A computer system can then be configured with an IP address on the same IP subnet and the webpage configuration can be loaded for viewing and changing the IP address as described in the section Accessing The Web Page Interface The device will remain at the default IP address until rebooted at which point it will revert to the assigned network settings 5 2 Unexpected reboots If the device is...

Page 57: ...ugh 100 Deg C Operating Temp 0 Through 75 Deg C Humidity 0 Through 90 Non Condensing Warranty 2 Years Parts Labor SDI Video Connector type BNC Data Types SMPTE 259M 292M 424M Data Rates 19 Mbit s through 3 0 Gbit s Re clocking Data Rates 270 Mbit s 1 485 Gbit s 2 97 Gbit s Input Output Return Loss 15dB HD 12dB 3G Input Level 800 mV P P 20 Input Impedance 75 Ohms 1 Cable equalization 1694A coax 400...

Page 58: ... Audio levels Level numbers start from 1 Mascot Protocol An abbreviation of MAtrix Switch COrporation proTocol An ASCII text based protocol for interfacing to Matrix Switch Corporation devices Matrix Used when referring to a Router s entire routing state Mute When supported a destination can be muted which for video means the output is turned off and for audio means it is silenced Output Synonymou...

Page 59: ...MSC XD164L Product Manual devices for remote panel control the MASCOT network interface and the web page interface Page 59 of 60 2013 2018 Matrix Switch Corporation www matrixswitchcorp com ...

Page 60: ...which shall be placed on the outside of the shipping package 6 This warranty does not apply if the product has been damaged by accident abuse misuse misapplication or modification EXCEPT AS SET FORTH ABOVE NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE MSC EXPRESSLY DISCLAIMS ALL EXPRESS OR IMP...

Reviews: