background image

14

Certification and quality assurance

The MPS-3600H series of programmable DC power reaches all the technical specifications
specified in the manual.

QA

The company guarantees the quality and quality of this product for one year from the date
of shipment.

Maintenance service

If the product is to be repaired, please send the product back to the designated
maintenance unit of our company. The customer must bear the one-way freight to send
the repair product to our maintenance department. The company will be responsible for
paying the return freight. If the product is returned to factory maintenance from other
countries, all the freight, tariff and its duties must be borne by the customer.

Quality assurance restriction

The above warranty does not apply to any damage caused by the following circumstances:
Customers are incorrect or improper in repairing products.
Customers use other software or interfaces.
Unauthorized modification or misuse;
Operate the product outside the designated environment, or configure and maintain it at a
non designated maintenance point.
The damage caused by the circuit installed by the customer.

Announcement

The contents of this manual are subject to change without prior notice, and the power of
interpretation belongs to the company.

Summary of Contents for MPS-3600H Series

Page 1: ...User Manual MPS 3600H Series Programmable DC Power Supplyl I psiv3600 series programmable straight MPS 3600H series programmable DC power supply MATRIX TECHNOLOGY INC Version No 20200506V1...

Page 2: ...N 7 4 3 VOLTAGE SETTING OPERATION 7 4 4 CURRENT SETTING OPERATION 7 4 5 SAVE RECALL OPERATION 7 4 6 BATTERY CHARGING WARNING FUNCTION 7 CHAPTER 5 REMOTE OPERATION MODE 8 5 1 COMMUNICATION BETWEEN POWE...

Page 3: ...duct of ordinary programmable power supply and has high cost performance advantages This series of power supply has the following characteristics Infinite servo intelligent fan system Multi group data...

Page 4: ...nd the power supply of MPS 3600H series At the same time we will tell you the basic inspection to ensure the normal operation of this product after getting the power supply 3 1 Front and back panel in...

Page 5: ...r part of the front panel is 0 9 numeric keys and ESC exit keys from left to right function keys up and down movement keys and Enter keys input and output terminals MPS 3600H series rear panel layout...

Page 6: ...eive the following attachments when you receive the power supply If there is any missing please contact your nearest dealer A power cord in line with the voltage standards used in the region An operat...

Page 7: ...panel operation introduction Voltage setting operation Current setting operation Storage operation Menu operation Output turn on off operation 4 1 Keyboard Arrangement Keynote description Key positio...

Page 8: ...c introduction to the key operation of front panel The C machine controls switching When the operation mode changes the output parameters of the power supply will not be affected 4 3 Voltage Setting O...

Page 9: ...key 0 to 9 numeric keys and press the Enter key to store the power parameters in the specified storage area You can use the Recall key 0 to 9 numeric keys and press the Enter key to remove the paramet...

Page 10: ...set cursor position Chapter 5 Remote Operation Mode 5 1 Communication between power and mainframe The power supply can be connected to the host interface through the level conversion circuit through t...

Page 11: ...Each command contains many strings mnemonic symbols and the layers are separated by colon The command at the top of the command tree is called root command or root To access the next command a path mu...

Page 12: ...he parameters 12 and the volt command ASCII code is 32 The command set of SCPI is not sensitive to case that is the command is not case sensitive and each command has a terminator for the EOI instruct...

Page 13: ...Return command None Example if the power is in remote control mode PC at this time send the command SYST LOC LF After the transmission is successful the front panel of the power supply has been set to...

Page 14: ...ut bool 1 the command is used to set the output of the power to turn on or not Return command None Parameters type bool parameters 0 OFF 1 ON Example the sending instruction is OUTP 1 LF After the tra...

Page 15: ...trument or carry out any unauthorized modification Please send the instrument to our maintenance department for maintenance so as to ensure its safe use Please refer to the specific warnings or precau...

Page 16: ...the return freight If the product is returned to factory maintenance from other countries all the freight tariff and its duties must be borne by the customer Quality assurance restriction The above wa...