20
Adapters
Adapter (9):
For standard valves with an internal diameter of
8 mm.
Adapter(10) :
For inflatable items with a screw valve. Deflation
is only possible with an unscrewed valve and
with this adapter.
Adapter(11):
For inflatable items with a deflation valve.
NOTE
·
The LED working light (7) is lit when the ON/
OFF switch (6) is lightly or fully depressed.
This allows illumination of the working area
while inflating in low light conditions.
Operating the cordless
compressor
This appliance is not designed for continuous
operation. The appliance may be used for a
maximum of 10 minutes continuous operation.
If the appliance overheats, remove the battery
pack (16). Allow the appliance to cool down
completely and then try using it again.
Display indicator
·
Press the ON/OFF switch (14) on the display
(12) or press the ON/OFF switch (20) to switch on
the display indicator (12).
·
The last set pressure is displayed for 2 seconds.
·
After two seconds, the current pressure of the
connected item is shown.
NOTE
·
If the compressed air hose is not connected
to a suitable item, the display indicator (12)
shows „0“.
·
If the display indicator (12) is switched on, you
can switch between "bar" and "psi" by pressing
the ON/OFF button (14).
·
To switch off the display indicator (12), press the
ON/OFF button (14) for 3 seconds.
NOTE
·
The compressor will not work if the display
indicator (12) is switched off.
Setting the pressure
·
Hold down the „+“ (13) or „–„ (15) button until
the display flashes.
·
Press the „+“ (13) or „–„ (15
)
button to set the
desired pressure.
·
Once you see the desired pressure on the
display indicator (12), do not press any button
for about 3 seconds. The desired pressure is now
set.
NOTE
·
The display indicator (12) (and thus the
compressor) switches off after around three
minutes of inactivity.
TIP
·
If you press and hold the „+“ (13) or „–„ (15)
button, the pressure changes quickly.
Initial operation
·
Loosen the cap nut (23) (do not unscrew it
completely!), twist in the compressed air hose
threaded connection (22a) and retighten the
cap nut (23).
·
Select the desired pressure.
·
Screw one of the supplied adapters ( 25, 26, 27,
28,29 , 30) tightly onto the compressed air hose
adapter (22).
·
Connect the adapter ( 25, 26, 27, 28,29 , 30) or
(30) to the object to be inflated.
·
Press the ON/OFF switch (20).
·
The compressor switches off automatically
when you reach the preset pressure.
·
Pull the adapter ( 25, 26, 27, 28,29 , 30) or (30)
out of the now inflated item.