37
cHAPTeR 8: TRoUblesHooTing
8.2 eRRoR coDe lisT - conTinUeD
CODE
CLASS
DESCRIPTION
MACHINE
SOLUTION
0147
B
Incline motor disconnection
A
a.
Please check the incline motor wire connection between the incline
and LCB.
b.
Please check the incline motor VR if there’s data.
-
If there’s no data, replace the incline.
-
If there’s data, replace the LCB.
T
a.
Please check the incline motor wire connection between the incline
and MCB.
b.
Run auto calibration.
c.
If the issue is not solved by replacing the incline motor.
0148
(01A7)
B
Incline motor over current.
A
a.
Don’t fix the incline motor tube then turn on the power.
-
If the console still shows error, please replace incline motor.
-
If the console does not show error, please follow the incline
motor installation SOP to fix incline motor.
b. Replace LCB.
0149
B
The resistance current is
over
A
a.
Please check if the resistance is short circuit.
-
If resistance data is under 10 ohms, please replace power
resistance.
-
If resistance data is over 10 ohms, please replace LCB.
02AB
C
Machine type error.
ESHURA
a.
Change the machine type on the console to match the correct
frame.
02AD
C
MCB is over temperature
T
a.
Check if that both fans are operating (there is a fan mounted to the
MCB itself as well as an external fan). Also check the connection
of the fans at the MCB.
b.
If the fans are running correctly, replace the MCB.
02A0
C
Encoder error
C
a.
Check the connection of the speed sensor cable from the LCB to
the speed sensor.
b.
Check to see if LED D35 on the LCB is on when the brake is
turned to the left release position.
c.
If LED D35 is off, move the stairs about 3 stairs and check to see
if LED D35 is flashing.
-
If not, replace the speed sensor.
-
If yes, adjust the speed sensor position and clean the speed
sensor of any debris then re-test.
02A2
C
Over DC bus voltage
T
a.
Please check if the input power is normal(110V : over 140V/ 220V:
over 280V)
b.
Replace the MCB.
02A3
C
Low AC power input voltage
when motor running
T
a.
Please check if the input power is normal(110V : low 76V/ 220V:
low 186V)
b.
Replace the MCB.
02A7
C
over I rms of phase current
of motor
T
a.
Please check the Motor wire connection between the Motor and
MCB.
b.
Please use the electric meter to check the 3 points (U/V/W) and
see if there’s data of inside impedance.
-
If yes, replace MCB.
-
If no, replace Motor set.
02BA
C
The inner memory IC data
read error.
T
a.
Reboot power, if error shows again, replace the MCB.
02BB
C
Inverter hardware interrupts
error.
T
b.
Reboot power, if error shows again, replace the MCB.
02BC
C
Ground connection or fuse
error
T
a.
Check the Motor wire (3 points U/V/W) and ground wire whether
short.
b.
Replace the MCB.
02BD
C
Drive hardware interrupt
error.
T
a.
Replace MCB.
02BE
C
DC brake error.
C
a.
Check the power extend wire connection between the brake and
LCB for any damage.
b.
Check to see if the stairs will move when you are in the stop posi-
tion. If yes, replace the brake.
02BF
C
DC brake Over Current
C
a.
Check the power extend wire connection between the brake and
LCB for any damage.
b.
Check to see if the stairs will move when you are in the stop posi-
tion. If yes, replace the brake.