34
NO POWER TO THE CONSOLE
POSSIBLE CAUSES:
1) The unit is not getting power from the outlet.
2) The LCB is not getting power from the power receptacle.
3) & 4) The LCB LEDs are lit, but there is no power to the console.
SOLUTION:
1) Verify power at the outlet. If the outlet is not outputting 120V, check the fitness room power.
a. Remove the front disk and check to see if LED9 is lit on the LCB. If it is not, verify power at the outlet. If the outlet is not outputting
120V, check the fitness room power.
b. If LED9 is still not lit after verifying the fitness room power, replace the power cord.
2) Check to see if LED9 is lit on the LCB (Figure A).
a. If LED9 is not lit, check for incoming AC voltage at the LCB. Replace the power components as needed if the voltage is not present.
b. Replace the LCB if all power components are ok and there is AC voltage to the LCB.
3) Check to see if LED D18 is lit on the upper control board (Figure B).
a. If LED D18 is lit, check the switch on the IO board, it should be towards the right side (LCB_Power - Figure B).
b. If LED D18 is not lit, check the console cable for connection at the LCB and console.
4) If LED D18 is not lit after checking the console cable connections, replace the console cable.
a. If LED D18 is lit on the console, but there is still no power, replace the console.
8.10 TROUBLESHOOTING - NO POWER TO THE CONSOLE
FIGURE B
FIGURE A
CHAPTER 8: TROUBLESHOOTING
Summary of Contents for E 7 X - 0 3
Page 1: ...E 7 X 0 3 S U S P E N S I O N E L L I P T I C A L S E R V I C E M A N U A L ...
Page 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION SERIAL NUMBER LOCATION ...
Page 27: ...24 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING ...
Page 28: ...25 CHAPTER 8 TROUBLESHOOTING 8 1 ELECTRICAL DIAGRAMS CONTINUED P21 DIGITAL COMMUNICATION WIRE ...
Page 29: ...26 8 1 ELECTRICAL DIAGRAMS CONTINUED CHAPTER 8 TROUBLESHOOTING G14 HAND PULSE CONNECTING WIRE ...
Page 87: ...84 NOTES ...