Matrix
150
Vision System Manual
A door lock should be connected to the relay port as shown below:
DC volta ge
Door lock Unit (Norma lly close)
D
o
o
r
House
Vision
Technical specifications of relay port:
• The external devices that can be operated by this relay port should conform to the specifications of it.
• The specifications of these relay ports are given below:
Contact arrangement
1 Normally Open
Contact Rating (Resistive load)
24 VDC @2A, 120VAC @1.0A
Maximum switching voltage
120V AC, 60V DC
Operate time
10 ms
Release time
10 ms
Expected electrical life
100,000 operations
Expected mechanical life
10,000,000 operations
How to program?
Step 1:
Program mode of operation of relay port using command
1801.
Step 2:
Program ‘ON’ time in relay port table using command
1802.
Step 3:
Program ‘OFF’ time in relay port table using command
1803.
Step 4:
Program the relay port ‘ON’ duration timer using command
3036.
Step 5:
Program the relay port ‘OFF’ duration timer using command
3037.
Step 6:
Operate the relay if programmed for total or partial manual mode using command
3990
and
3991.
Step 1
Use following command to program the mode of the relay port:
1801-Mode
Where,
Mode
Mode Type
0
Relay port deactivated
1
Total Manual
2
Duration based Auto OFF
3
Duration based Auto ON
4
Duration based Auto ON and Duration based Auto OFF
5
Time based Auto Off
6
Time based Auto On
7
Time based Total Auto
By default, Relay port is programmed for manual operation.