594
Matrix ETERNITY NE System Manual
•
The Operator sets Dynamic Lock for an extension by entering the extension number, selecting the Toll
Control Level, and setting the Dynamic Lock Timer.
•
Now, whenever a call is made from extension A, the system checks the Toll Control Level assigned to the
extension.
•
The system then checks the associated Lists of allowed and denied numbers.
•
If the Toll Control Level is 0, then Toll control is time zone based, i.e. Day and Night. The outgoing call
is allowed/denied as per the Call Privilege and the corresponding Allowed and Denied Number List
programmed for that time of the day by the System Engineer.
•
If the Toll Control Level is 1, 2, 3 the outgoing call is allowed/denied as per the Call Privilege and the
corresponding number list programmed for each level.
•
If Dynamic Lock - Automatic has been set by user/Operator, the system waits for the duration of the
Dynamic Lock Timer set for the extension. At the end of each outgoing call made during the period of this
Timer, the system will restart the Timer again. The system will change the Toll Control back to the pervious
Level when no outgoing call is made till the expiry of this Timer.
•
If Dynamic Lock - Automatic has been set by user/Operator, and an internal call is made during the period
of the Dynamic Lock Timer, the system will check for the '
Decrement Dynamic Lock Timer for Internal
Calls
' feature in the Class of Service of allowed to the extension.
If this feature is enabled, the system will start the decrement of the Dynamic Lock Timer. The system will
change the Toll Control back to the previous level on the expiry of this Timer. However, if the 'Decrement
Dynamic Lock Timer' feature is disabled in the Class of Service, the system will reset the Toll Control as
described in the previous step.
•
If Dynamic Lock - Manual has been set, the extension user/Operator must set the Toll Control Level back
to the previous Level.
Feature Interactions
•
Redial and Auto Redial:
The system will check for Toll Control Level when an extension, on which
Dynamic Lock is set, attempts Redial or Auto Redial.
•
Emergency Number Dialing:
All extensions will be able to dial Emergency numbers always, regardless
of the Toll Control set on them.
ETERNITY NE provides for a separate configuration of Emergency Numbers, which remain unaffected by
Dynamic Lock set on the phones. Refer the topic
“Emergency Dialing”
to know more about this feature.
How to configure
For this feature to work, it must be enabled in the Class of Service of the extensions; Toll Control Level must be
configured on the extension.
By default, Dynamic Lock enabled on all extension types during the Day and the Night. So, all extensions of
ETERNITY NE can set Dynamic Lock.
The 'Dynamic Lock Timer' is disabled in the Class of Service of all extension types.
Summary of Contents for ETERNITY NE
Page 1: ...ETERNITY NE System Manual ...
Page 2: ......
Page 3: ...ETERNITY NE The Next Generation IP PBX for Small Businesses System Manual ...
Page 10: ...vi Table of Contents ...
Page 24: ...14 Matrix ETERNITY NE System Manual ETERNITY NE3 ETERNITY NE ...
Page 26: ...16 Matrix ETERNITY NE System Manual ...
Page 60: ...50 Matrix ETERNITY NE System Manual ...
Page 260: ...250 Matrix ETERNITY NE System Manual ...
Page 292: ...282 Matrix ETERNITY NE System Manual ...
Page 298: ...288 Matrix ETERNITY NE System Manual Click the more link to expand options ...
Page 373: ...Matrix ETERNITY NE System Manual 363 Click Hardware to expand options ...
Page 884: ...874 Matrix ETERNITY NE System Manual ...
Page 912: ...902 Matrix ETERNITY NE System Manual ...