4.5 REPETITION MAGNET HAS FALLEN OFF OR IS MISSING
Possible Causes
1) The repetition counter magnet was not secured tightly enough to the repetition counter bracket.
Solution
1) Remove side covers and the 2 screws fixing the magnet frame (Figure A).
2) Install a zip tie to securely attach the magnet to the bracket (Figure B).
3) When installing the zip tie, make sure that the head of the zip tie is on the opposite side of the
bracket from the magnet so that the head does not interfere with the movement of the top weight
plate (Figure C).(1000232864)
Figure A
Figure B
Figure C