2.
Open the side covers then check if all the wire harnesses are
connected properly to the terminals of the control board and
confirm the control board +12 LED whether is light.
3.
Unplug the generator cable from the control board and pedal the
machine to check if the voltage is variable.
If it is, replace the control board with a new one.
If it is not, replace the generator with a new one.
No display on the console or the display is dim
Possible causes:
1.
Console is damaged or the console cable is not connected properly.
2.
Poor connection to all the terminals on the control board.
3.
Control board is damaged.
4.
Generator is damaged.
Fix:
1.
First, unplug the console cable and use a multi-meter to check if
the voltage between the 1(Vcc) and 7(Ground) pin of the console
cable is greater than 12 VDC.
(If it is, replace the console and check again.
Summary of Contents for MX-A5 Series
Page 1: ...1 MX A5x SERVICE MANUAL...
Page 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Page 6: ...6 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Page 7: ...7 MX A5x WIRING DIAGRAM INSTRUCTION...
Page 8: ...8 P05 Digital cable console cable P04 Pulse sensor wire...
Page 9: ...9 P02 Elevator Wire P14 ECB Load Wire...
Page 10: ...10 SECTION 3 CONSOLE ENGINEERING MODE GUIDE...
Page 12: ...12...
Page 13: ...13 MANAGER SCREN DESCRIPTIONS...
Page 14: ...14...
Page 15: ...15 SECTION 4 LCB3 LED INSTRUCTIONS...
Page 17: ...17 SECTION 5 TROUBLESHOOTINGS...
Page 32: ...32 SECTION 6 Part Replacement Guide...
Page 36: ...36 Step6 Put the incline motor tube on fixed stand Step5 Fix the incline motor...
Page 38: ...38 SECTION 7 SOFTWARE UPGRADE PROCEDURE...
Page 41: ...41 Install the MSP430 Tools Computer...
Page 42: ...42 Press the Load Image Installation software to MSP430 Tools...
Page 43: ...43 Installing the MSP430 cable to console MSP430...