Fix:
1.
Remove the console and check if the console cable has been
connected properly.
2.
Remove the side covers and check if the console cable is connected
well to the control board properly and confirm the LCB
RBK
LED
whether is light. If not light, please replace the LCB.
3.
Please make use of tools to confirm “Generator” have
conduct(10~15
Ω
).
No resistance change or too hard for pedaling
Possible causes:
1.
Console is damaged or the console cable is not connected properly.
2.
Console cable is damaged.
3.
Power resistance is damaged.
4.
Control board is damaged.
If it is damage, Please replace “power resistance”
If it is well, Please replace LCB
Summary of Contents for MX-A5 Series
Page 1: ...1 MX A5x SERVICE MANUAL...
Page 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Page 6: ...6 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Page 7: ...7 MX A5x WIRING DIAGRAM INSTRUCTION...
Page 8: ...8 P05 Digital cable console cable P04 Pulse sensor wire...
Page 9: ...9 P02 Elevator Wire P14 ECB Load Wire...
Page 10: ...10 SECTION 3 CONSOLE ENGINEERING MODE GUIDE...
Page 12: ...12...
Page 13: ...13 MANAGER SCREN DESCRIPTIONS...
Page 14: ...14...
Page 15: ...15 SECTION 4 LCB3 LED INSTRUCTIONS...
Page 17: ...17 SECTION 5 TROUBLESHOOTINGS...
Page 32: ...32 SECTION 6 Part Replacement Guide...
Page 36: ...36 Step6 Put the incline motor tube on fixed stand Step5 Fix the incline motor...
Page 38: ...38 SECTION 7 SOFTWARE UPGRADE PROCEDURE...
Page 41: ...41 Install the MSP430 Tools Computer...
Page 42: ...42 Press the Load Image Installation software to MSP430 Tools...
Page 43: ...43 Installing the MSP430 cable to console MSP430...