4.2 MAnAGer screen DescriptiOns
•
p0
:
Maximum progam time
-
Sets the total run time of any program.
•
p1
:
Default workout time
-
Workout time when
qUick stArt
is pressed or when no time is
selected during program set up.
•
p2
:
Default resistance level
-
Starting resistance when
qUick stArt
is pressed or no resistance
level is selected during program set up.
•
p3
:
Default user weight
-
Weight used for program calorie expenditure calculations.
•
p4
:
speed Units
- Display value in miles or kilometers.
•
p5
:
Machine type
-
Console is shared between the A5x and I5xi. A5x default setting is
“
sWinG
” and I5xi default setting is “
rAMp
”.
•
p6
:
console beep on / off
- Confirmation beeps can be turned on or off.
•
p7
:
Accumulated distance
- Total distance of all programs.
•
p8
:
Accumulated time
- Total accumulated program time displayed in hours.
•
p9
:
Display language
-
Select between English, Spanish, French Italian, Dutch and German.
•
p10
:
software version
-
Current version of software. Refer to this when calling Matrix Technical Service.
•
p11
:
incline calibration
-
Default display is
Off.
Selecting
On
will automatically calibrate the
incline motor (s) to factory settings. Use this feature when actual
elevation does not match console display.
•
p12
:
incline reset
-
This is a software feature that resets machine elevation to 0 degrees
after 30 seconds of user inactivity. During incline reset, movement
can be stopped by pressing any console key. Display will scroll “
HOlD
select tO resUMe
”. To resume reset to 0 degrees, hold “
select
”key
for three seconds.
•
p13
:
Default incline level
-
Starting incline level at each program start except
FIT TEST.
Factory setting is 10%. In FIT TEST, elevation is set to 0%.
•
p14
:
error code
-
Console will record up to three errors. Error codes are stored permanently
unless reset by a technician. To reset error codes, hold
MAnUAl
and
rAnDOM
keys for three seconds. Refer to these error codes when
calling Matrix technical service for assistance.
•
p15
:
lcB version
-
Display will show LCB.VER XX YYY.
XX is machine type.
YYY is version number.
cHApter 4: p
rogramming
& e
ngineering
m
ode
cODe: infOrMAtiOn
DefAUlt
Min
MAX
p0
:
Maximum progam time
-
95 min
10
95
p1
:
Default workout time
-
20 min
10
MAX
p2
:
Default resistance level
-
1
1
25
p3
:
Default user weight
-
150 lbs. /75 kg
80
400
p4
:
speed units
-
mi
p5
:
Machine type
-
Swing
Ramp
p6
:
console beep on / off
-
on
p7
:
Accumulated distance
-
p8
:
Accumulated time
-
p9
:
Display language
-
English
p10
:
software version
-
p11
:
incline calibration
-
p12
:
incline reset
-
on
p13
:
Default incline level
-
10
0
100
p14
:
error code
-
nOte
: DEFAULT TIME will update to the same as MAX TIME if MAX TIME is less
than DEFAULT TIME.
4.3 enGineerinG MODe
to enter engineering mode
, hold the
Up
and
DOWn
elevation keys for three
seconds until “
MAnAGer
” appears on the middle LED display. Press the
DOWn
arrow key and “
errOr cOntrOl
” will appear on middle LED display.
error control
, Do not use this mode unless you are a qualified technician. Error
control will determine if a machine is disabled once Class A or Class B errors
are registered by the software.
incline record
, log of incline motor and total program activity. This record holds
the total number of hours for each program (MANUAL, ROLLING, INTERVAL,
etc.) as well as incline motor activity in hours. This can be a useful tool for the
club manager of trainer when reviewing machine usage.
• To enter INCLINE RECORD, press
select
when
incline recOrD
is
displayed.
• Totals are stored permanently unless reset by a technician. To reset error codes, hold
MAnUAl
and
rAnDOM
keys for three seconds. Refer to accumulated hours when
calling Matrix technical service for assistance. (Insert chart)
incline tuner
, Do not use this mode unless you are qualified technician. Incline
Tuner allows calibration and resetting of the incline motor range of motion.
service 1,2,3,4
are described in the Matrix Technical Service Guide.