Matrix SETU ATA211 System Manual
29
•
For the number you entered, define the
Maximum Digits
. The number received must not
exceed the maximum digits you have defined here. Default:24
•
For the number you entered, select the
Destination Route.
It may be the FXS or FXO port to
route the Called Party number.
Click
Submit
and close the window. To know more see “Called Party Number Table”
.
2.
Enter the
Fixed Destination Number
in this field, if the incoming call routing option requires the call to be
finally placed at a fixed destination. You can configure the fixed destination number of maximum 16 digits.
Default: Blank
3.
Enter the time duration in the
Ring Timer
field, for which the system plays the ring on the FXS Port for an
incoming call. Range of the ring timer is of 01 to 99 seconds. Default: 45 sec.
4.
To display
CLI Number on FXS Port
2
, you may select:
•
Calling Number
•
Called Number
Default: Calling Number
5.
Define the type of response the system should send on the receipt of an incoming call on the SIP trunk.
For the
On Connecting Media, Send
parameter, you may select:
•
183 Session Progress
•
200 OK
Default: 183 Session Progress
6.
If you want to
Authenticate Incoming Calls
on SIP, that is, you want to allow incoming calls only after
callers have authenticated themselves. You can select:
•
Pin Authentication
: Select this option to authenticate callers with a unique PIN.
•
Digest Authentication
:Select this type of authentication if you want to allow incoming calls on the SIP
Trunk only after callers have authenticated themselves with their User ID and Password
.
Default: Disabled.
If you have selected
Pin Authentication
, you must configure the PIN Authentication Table.
To do this,
2. SETU ATA211 supports display of Calling Line Identity (CLI) on the FXS Port, depending on number received in the request SIP mes-
sage.