Matrix SETU VFXTH System Manual
180
Call Disconnect Tone
If Call Disconnection is signaled by your CO Network in the form of Disconnect Tone, configure
Disconnect Tone
on the FXO Ports. You must enable
Disconnect Tone Detection
on the
FXO Port
and select the
Disconnect Tone
Type
.
To enable the system to detect the Disconnect Tone accurately, you must configure the Cadence (ON-OFF time)
and Frequency of the Disconnect Tone Type you selected, as supported by the CO network. To do this,
•
Log into Jeeves.
•
Click the
Advanced Settings
link.
•
Click the
Disconnect Tone
link. The Disconnect Tone Cadence Table opens.
•
For each Disconnect Tone, set the following parameters:
•
Frequency 1 (Hz):
Frequency 1 is from 300 to 1400 Hz.
•
Operator:
This parameter has 3 options: No operator, Modulation (*), Addition (+)
If Modulation is selected, frequency 1and frequency 2 will be used as modulation i.e. F1* F2
If Addition is selected, frequency 1 and frequency 2 will be used as addition i.e. F1 + F2.
If No Operator is selected, frequency 2 will not be applicable.
•
Frequency 2 (Hz):
Frequency 2 is from 20 to 1400 Hz. Select Frequency 2 if the Disconnect Tone
supported by the CO network consists of Dual Frequency.
•
Cadence:
Configure the ON Time1-OFF Time1, ON Time2-OFF Time2 and ON Time3-OFF Time-3 for
each Disconnect Tone. Valid ON Time and OFF Time range is 0000-9999 milliseconds.
When the system detects disconnect tone on the FXO Port and if it matches with the Frequency and
Cadences you have set, the call will be disconnected and the FXO Port will be released.
•
Click
Submit
to save.