Matrix SETU VFXTH System Manual
226
•
Select the
Protocol for Auto Firmware Upgrade
to be used by the Provisioning Server to upgrade the
firmware of SETU VFXTH. SETU VFXTH generates file transfer request to the server according to the
protocol you select. You may select
HTTP
or
HTTPS
.
Default: HTTP.
•
Server Address: Port:
Enter the IP Address/Domain and Port of the Provisioning Server on which the
firmware files of SETU VFXTH are stored.
The Provisioning Server Address can also be obtained by SETU VFXTH using DHCP (using Option
224). To fetch Provisioning Server Address using DHCP, keep the Server Address: Port field blank.
If you want SETU VFXTH to get the Server Address from the DHCP server, keep this field blank. Make
sure that you also set the
Connection Type
on the
page to
DHCP
.
The default Port differs as per the protocol you select. For HTTP, the Default Port is 80 and for HTTPS,
the Default Port is 443. You can also change the port as per your requirement. Valid Port Range: 80,
443, 1031 to 65534.
•
Firmware Folder Path:
Specify the path of the folder on the Provisioning Server where the firmware
files are stored. Default: Blank.
•
Upgrade Firmware Automatically at Every Power ON:
Enable this check box, if you want SETU
VFXTH to check for updates in the firmware at each power ON.
•
At Power ON, if both Auto-Firmware upgrade and Auto-Configuration upgrade is enabled, Auto-
Firmware upgrade has priority over Auto-Configuration upgrade.
•
While upgrading itself, if SETU VFXTH has to upgrade itself with the benchmark firmware first then it is
recommended that you select
Upgrade Firmware Automatically at Every Power ON.
•
Upgrade Firmware Automatically at Scheduled Time:
Enable this check box, if you want SETU
VFXTH to check for updates in the firmware at a scheduled time. You may select any one of the
following schedule options:
•
Every XX minutes:
The minutes after which SETU VFXTH should check for firmware updates.
•
Everyday at HH:MM:
The time in
Hours(00-23)
and
Minutes(00-59)
when SETU VFXTH should
check for firmware updates everyday.
•
Every Month on DD at HH:MM:
The
Date (01-31)
and Time in
Hours (00-23)
and
Minutes(00-59)
when SETU VFXTH should check for firmware updates every month.
If SETU VFXTH has to upgrade itself with the benchmark firmware and you have selected
Upgrade
Firmware Automatically at Scheduled Time
, SETU VFXTH will first upgrade itself with the benchmark
firmware. At the next scheduled time, it will upgrade itself with the final firmware.
•
Request Timeout:
Request Timeout is used when SETU VFXTH tries to connect to the Provisioning
Server for TCP/TLS binding. This timer specifies for how long SETU VFXTH should wait for successful
TCP/TLS binding.
Enter the required time in seconds. The range of Request Timeout is 01-99 seconds. Default: 60
seconds.