Matrix SETU VFXTH System Manual
58
Default: Disconnect Tone 1
If required, you can customize the frequencies and cadences of the Disconnect Tone as per your
requirement. See
•
You may configure the
Ring Cadence-OFF Timer
for the FXO Port to set OFF time for Ring cadence.
During an incoming call on the FXO Port, if the CO gives ring with a long Ring OFF period, the system will
consider that the ring has been stopped, and it will stop ringing the FXS Port, even though the incoming
call is still present.
To get correct indication, the system supports the Ring Cadence OFF timer on the FXO Port so that ring
can continue, even for incoming calls with long Ring OFF period.
The range of the Ring Cadence OFF timer is from 1 to 9 seconds. Default: 5 seconds.
•
Configure the
Flash Timer
, as per your requirement. The Flash timer signifies the time period for which the
loop current breaks. SETU VFXTH uses this event to activate various features such as Call Hold, Call
Transfer, etc. Default: 600 milliseconds.
•
Configure the
Pause Timer
to add delay, while a call is being made from the FXO Port. After the FXO Port
goes Off-hook, SETU VFXTH adds some delay before dialing out the number. During this time, no digit is
dialed by the system on the FXO Port. This is used when the exchange takes some time to detect that the
FXO Port is Off-hook. Default: 500 milliseconds.
This timer will also be used while applying ANT logic, if you have configured Pause (^) in the Add Prefix
column of ANT table. See
“Automatic Number Translation (ANT)”
for more details.
•
Select the appropriate
Dial Type
option as supported by your CO Network. You can select either Pulse or
DTMF. Default: DTMF.
•
If you have selected the
Dial Type
as
Pulse
, you must set the
Pulse Dial Ratio
as per your country.
You can select the required pulse dial ratio from the following options: 40:60, 50:50 and 33:67. Default:
33:67.
•
In the
DTMF Dialout On Time
field, set the time as per the CO network. The DTMF On Time is the time for
which the DTMF digit which is to be out dialed remains ON. Valid range: 50 to 200 milliseconds. Default:
70 milliseconds.
•
In the
DTMF Dialout Off Time
field, set the time for which system should wait before dialing the
successive DTMF digits so that the CO network can detect the dialed digits. Valid range: 50 milliseconds to
200 milliseconds. Default: 70 milliseconds.
•
Select the
Allow Call Disconnection using Access code
check box,
if you want to enable the feature
Disconnect Call using Access Code on the FXO Port. See
“Disconnecting a Call using Access Code”
•
Click
Submit
to save the settings.