20
8.4 0140 / 01a0 / 01a2 error TroUbleSHooTiNG
error meSSaGeS 0140 / 01a0 / 01a2
1) sYmPtom:
a. 0140 - Incline motor operation failed.
b. 01A0 - Incline motor disconnected.
c. 01A2 - Incline motor is detected in the reverse of the position indicated by the potentiometer.
2) solution
a. Check the connection of the incline motor cable at the MCB.
b. Run auto calibration (See Section 3.4).
c. If auto calibration fails, re-enter Engineering Mode and scroll until Elevation Minimum is displayed, then press ENTER.
- Check the MCB LEDs. If LED DOWN (Figure A) has no light, check the console cable connections at the console and MCB.
Replace the console or cable as needed. If LED DOWN has a light, replace the incline motor.
d. If the incline motor does not resolve the issue, replace the MCB.
fiGUre a
8.5 01a3 error TroUbleSHooTiNG
error meSSaGe 01a3
1) sYmPtom:
a. Motor is disconnected.
2) solution:
a. Check the connection of the motor cable at the MCB (Figure A).
b. Check to see if the MCB LED DSP1 (MCU) is lit (Figure B).
c. If LED DSP1 is blinking, the motor should be replaced.
d. If LED DSP1 is a solid light, replace the motor.
e. If LED DSP1 is not lit, replace the MCB.
fiGUre a
fiGUre b
CHaPTer 8: TroUbleSHooTiNG