18
8.3 TROUBLESHOOTING - ERROR 04A0 / 0440
FIGURE A
FIGURE B
CHAPTER 8: TROUBLESHOOTING
ERROR CODE 04A0 / 0440
1) SYMPTOM:
04A0 – UCB communication disconnected.
0440 – Timeout receive packet (LCB can not receive any data for 50 seconds).
2) SOLUTION:
If the display is giving a 04A0 error, check the LCB LED10 status.
- LED10 blinking: Turn off power and after 3 seconds, turn on power again. If console also show the 04A0, re-install UCB software again. If
this does not resolve the issue, replace the UCB.
- LED10 off: Check the connection of the digital communication wire at the UCB and LCB (Figures A & B). If the connection is good,
replace the digital communication wire.
- If replacing the UCB and digital communication wire does not work, replace the LCB.
Summary of Contents for U3X-05
Page 1: ...U 3 X 0 5 B I K E S E R V I C E M A N U A L...
Page 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION FRAME SERIAL NUMBER LOCATION...
Page 15: ...12 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING...
Page 16: ...13 8 1 ELECTRICAL DIAGRAM CHAPTER 8 TROUBLESHOOTING...
Page 19: ...16 8 1 ELECTRICAL DIAGRAMS CONTINUED CHAPTER 8 TROUBLESHOOTING PULSE EXTENDED WIRE...
Page 20: ...17 8 2 LCB LED INDICATORS CHAPTER 8 TROUBLESHOOTING...
Page 73: ...70 NOTES...