24
CHAPTER 8: TRoUBlESHooTINg
8.8 TRoUBlESHooTINg - ERRoR 01AC / 01Af
fIgURE A
ERRoR CoDE 01AC / 01Af
1) SyMPToM:
01AC – Electro-magnet over current.
01AF – Electro-magnet disconnected.
2) SolUTIoN:
1) Check if the Electro-magnet is short circuited or open (Figure A).
- If the resistance data shows a short / open ohms or is outside the range of 12.8 ~14.2 ohms, replace the Electro-magnet.
- If the resistance data is in the range between 12.8 ~14.2 ohms, replace the LCB.