5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all; Display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-6, 5-7
Summary of Contents for M130TCS
Page 9: ...SCHEMATIC DIAGRAM 4 3 OVEN THERMAL CUT OUT MGT THERMAL CUT OUT ...
Page 28: ...6 2 13536A 15006A 13552A 13213A 13352A 13720D 14970A 14026A 13581A DOOR PARTS EV ...
Page 29: ...6 3 24781M 268711 WTP015 250201 23506A 24510L 23572A 24970A 23550D CONTROL PANEL PARTS EV ...
Page 30: ...6 4 34036W 34960A 36549S 33112U WTT021 WTP013 33052A 33390G 35889A OVEN CAVITY PARTS EV ...
Page 31: ...6 5 466001 43500A 466001 466003 WSZ085 43501A LATCH BOARD PARTS EV ...
Page 33: ...6 7 63303A 63302A WTT021 WSZ002 65006B 56170D 948501 BASE PLATE PARTS EV ...
Page 34: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 35: ...8 2 PRINTED CIRCUIT BOARD ...
Page 36: ......