5-16
Output is full power
when you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
Summary of Contents for M130TCS