Lock voltage and current setting dial. 
This mode is good for purpose to avoid 
changing output setting by mistake or 
when easy emergency stop is required.  

Lock all the function other than reset 
lock mode. This mode is good for 
purpose to avoid mis-operation 
complelely. 

Function to select two different lock modes for two different 
purposes."Full Lock" locks all the functions on front panel, and 

"Normal Lock" locks all the functions except for ON/OFF switch. "Full 

Lock" mode shall be good in case mis-operation have to be 
completely avoided, and "Normal Lock" mode shall be good in case 
to avoid mis-operation but secure the way for emergency stop of 
power supply. You can select the best mode according to your level 
of "Security".
 (In both modes, emergency stop is possible with Power Switch.) 

Function to output ON/OFF of total 32 units from one master 
unit.(when Master/Slave)

*

 It is possible to delay the ON/OFF time, 

and simultaneous ON/OFF setting is possible as well. Ideal 
function for application which requires to turn on power one by 
one or time lag.

Dual tracking control, which enables both positive and negative 
outputs simultaneously in master slave operation, is possible. Multi 
outputs and various versatile operations are also possible by 
combining above dual tracking control and slave local mode. 
Positive and negative V, -V) of dual tracking control and 
set output voltage of slave local mode can be output 
simultaneously by turning on the master unit. 

*

Please refer to P.10  for detail connection.

Function to memorize 3 different voltage and current settings in 
addition to standard preset function.

No need to adjust the output when different setting, and 
convenient function for production inspection process or testing 
which require frequent data taking.

Memory a

Memory b

Memory c

3

Set voltage and current

1

2

Press down SET
Select a memory
with 3 buttons

<NOTE>  It is not possible to stabilize the output by controlling back current. In case of load which 
has inverse voltage or over rated voltage, such as inductive load or regenerative motor, protect the 
power supply by adding dummy resister or diode to prevent back current.

Battery

Prevent back current

REK series features 

function to sink current

, and enable to decrease 

the voltage quickly when turning off the output or when control the 
voltage down, which increase the safety of operation. In case that 
continuous aging test in short interval, quick voltage fall time increase 
the efficiency of process. On the contrary by using 

sink current 

prevention

 function, it is possible to prevent voltage drop on the load by 

decreasing the current flow from load to power supply when turning off 
the power supply or when decrease the output voltage.

Master

Master

Master

Master

Master

t 1

t 5

t 2

t 6

t 3

t 7

t 4

t 8

OUTPUT OFF

(From Master)

Up to 32 units

*setting  range of t1 to t8 is 0.0s to 99.9s

Slave1

Slave remote

Slave remote

Slave remote

(Output following Master)

Slave local

Slave local

(The value set by front panel)

Slave2

Slave3

OUTPUT ON

(From Master)

*

Master/Slave function is available on the model without -LGob, -LUs1, -LEt and -LDc

  option. Also Master/Slave is not available when using -LDe function.

Dual Tracking

Dual
tracking

Multiple Outputs

OUTPUT ON

(at Master)

Slave remote

(Output following Master)

+

+

+

+V

0

-

V

OUTPUT ON

(at Master)

+V

1

+V

2

0

-

V

Master

Slave remote

Slave local

Slave remote

Standard function

Sink Current / Sink Current Prevention Function

Multi Setting Function

Two Mode Lock Function

Delay Trigger Function

Dual Tracking, Multiple Outputs

04

Summary of Contents for REK Series

Page 1: ...nt Power Supply REK Series www matsusada com High power Versatile Programmable DC power supply Compact High power of 5 5kW except some models REK series NEW NEW except some models 6V to 650V 2 5A to 600A 1 6kW to 5 5kW ...

Page 2: ...cise monitoring with better recognition Operability and safety are improved with new features of key lock function and acceleration rotary encoder which accelerate the output ramp up with the speed of rotating the encoder 7kW 10kW models are also available 1 6kW to 2 5kW models 3 6kW to 5 5kW models Featuring broad output range and low noise switching configuration REK series is an ideal power sup...

Page 3: ... to 25 0 to 36 0 to 55 0 to 10 0 to 16 6 0 to 24 0 to 36 0 to 8 0 to 12 5 0 to 18 0 to 27 0 to 5 3 0 to 8 3 0 to 12 0 to 18 0 to 3 2 0 to 5 0 to 7 0 to 11 0 to 2 7 0 to 4 1 0 to 6 0 to 9 0 to 2 5 0 to 3 8 0 to 5 5 0 to 8 5 10 10 10 10 10 10 10 10 10 10 10 15 10 12 15 15 20 20 20 20 20 20 30 30 20 30 30 30 20 18 30 30 20 20 30 30 20 25 30 30 30 25 30 30 40 40 40 40 50 50 50 50 100 100 100 100 150 1...

Page 4: ...output when different setting and convenient function for production inspection process or testing which require frequent data taking Memory a Memory b Memory c 3 Set voltage and current 1 2 Press down SET Select a memory with 3 buttons NOTE It is not possible to stabilize the output by controlling back current In case of load which has inverse voltage or over rated voltage such as inductive load ...

Page 5: ...h range 1 0s to 99 9h respectively tb tc toff a b c ta t1 Note The operation accuracy of the timer when sequensing is 0 5 Be careful when you use it by the long term running operation t2 Output ON Output OFF t1 a c b ta t2 tb t3 tc t4 toff t1 and t2 can be set with range 0 to 999s respectively t1 t2 t3 and t4 can be set with range 0 to 999s respectively ta tb tc and toff can be set with range 0 0s...

Page 6: ...ogramming display Light on when voltage current remote control Output preset switch OVP OCP setting switch Keylock setting switch Exhaust hole AC input terminal M4 Not Sink Current switch 1 10 11 12 13 14 15 16 17 18 2 3 4 5 6 7 8 9 Front Panel Rear Panel nt Panel 1 1 2 3 6 5 8 9 1 0 11 12 13 14 15 4 7 Voltage Control 0 to approx 10k Current Control Blackout Protection Io Load VL Vo R S S OUTPUT 0...

Page 7: ...n Interlock Other functions Transient response time Operation temperature Storage temperature Storage humidity Dielectric voltage Accessories 50 Temp C Input Voltage V Input Voltage V Output Power kW 40 85 100 120 200 240 264 1 6 1 2 85 100 120 200 240 264 Keylock to avoid misoperation Digital master slave operation up to 250V for series operation Max 32 units for parallel or series connection Com...

Page 8: ... V COM ON when OUTPUT ON when each mode FLT OUTPUT CV CC TB1 ON when fault CV CC Delay trigger function at Master Slave control can be set for each unit Furthermore delay trigger function at Master Slave control can cancel one control functions except for Output by switching Remote Local and can set voltage and current preset Possible to change 10k to 0 for fail safe A A A RS 232C RS 485 GPIB A CO...

Page 9: ...8 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 4 M4 4 M4 3 Ø0 33 8 5 2 M6 1 38 35 0 18 4 5 16 85 428 16 81 427 2 36 60 17 17 436 Weight 8kg typ Weight 8kg typ Weight 14kg typ Weight 14kg typ 1 6kW 2 5kW Models 1 6kW 2 5kW Models 3 6kW 5 5kW Models 3 6kW 5 5kW Models O I 1 97 50 3 76 2 3 47 88 1 18 31 465 19 482 6 8 6x10 There are exhaust holes on rear panel for forced air cooling In case plac...

Page 10: ... 1 CO G32 B 32 units can be connected to 1 CO E32 32 units can be connected to 1 CO U32 In case power supply will be use following condition make sure this options selected Noisy environment such as factories ex usage of motor and coil around load or power supply Usage on high voltage floating more than 250V In case the distance between power supply and controller PC or PLC is longer than 2 meter ...

Page 11: ... is assured Important Notice F S catalog value is applied for ripple stability regulations and temperature coefficient and value if F S 1 is applied for high voltage output linearity monitor linearity and display linearity both in the range of 10 to 100 of maximum rating output Definition of specifications Connection Operation Applicable scope of specifications Please use a short lead wire that is...

Page 12: ...ed to be defective as satisfactory to us we at our sole discretion repair or replace such defective Products at no cost to the purchaser We assume no liability to the purchaser or any third party for special incidental consequential or other damages resulting from a breach of the foregoing warranty This warranty excludes any and all other warranties not set forth herein express or implied includin...

Reviews: