9 Voltage Shift Option
109
DOEF series
Matsusada Precision
9-7 Combined use with Communication Options
Products with the voltage shift option differ from products without the option in the maximum and minimum
units of voltage and current limit protection values, voltage cutoff protection value, DC voltage value, and
each measurement values.
Note that the initial values on the remote control also differ.
Table: Setting unit, minimum/maximum values for each command (Matsusada original command)
Function
Command
Setting unit
Min setting
Max setting
No. of
significant digits
DC voltage setting
DCVSET(?)
0.01V
-115.00V
+115.00V
5 digits
Positive voltage limit
VULIM (?)
0.1V
+5.0V
+115.0V
4 digits
Negative voltage limit
VLLIM(?)
0.1V
-5.0V
-115.0V
4 digits
Positive current limit
IULIM(?)
0.1A
0.1A
60% to 110% of rating
current
✽
1
4 digits
Negative current limit
ILLIM(?)
0.1A
0.1A
60% to 110% of rating
current
✽
2
4 digits
Voltage cutoff
OVPSET(?)
0.1V
0.1V
115.0V
4 digits
Voltage effective value readout
VRMSGET
0.01V
5 digits
Voltage DC value readout
VDCGET
0.01V
5 digits
Voltage AC value readout
VACGET
0.01V
5 digits
Voltage max value readout
VMAXGET
0.1V
4 digits
Voltage min value readout
VMINGET
0.1V
4 digits
✽
1 t will be determined depending on the positive voltage limit protection value.
✽
2 It will be determined depending on the negative voltage limit protection value.
Summary of Contents for DOEF Series
Page 1: ...Instruction Manual F RA 001 3R2 MODEL DOEF series B N 243 9 024 243 9 024 Rev 0 4 ...
Page 15: ...2 External Appearance 7 DOEF series Matsusada Precision 2 3 Dimensions 2 3 1 400W Model ...
Page 16: ...2 External Appearance 8 DOEF series Matsusada Precision 2 3 2 600W Model ...
Page 17: ...2 External Appearance 9 DOEF series Matsusada Precision 2 3 3 1200W Model ...
Page 121: ......
Page 123: ......
Page 124: ......