6 Master/Slave Option
91
DOEF series
Matsusada Precision
The display of the unit that activated protection due to an error detected is the same as a standalone
operation. The display of a unit that has been stopped due to an error occurred in another unit is as
follows.
Ex.: Display in a fault state due to OCP activated
Fig. Display in fault state
Display
Status
Trigger unit
FAULT (E24) OCP !
Fault state due to overcurrent
Master unit
FAULT (E22) OVP !
Fault state due to over voltage
Master unit
FAULT (E23) OPP!
Fault state due to sink-power
Each unit
OVER POWER !
State
in
which
sink-power
is
exceeding the setting value.
Master unit (only itself)
INTERLOCK!
Fault state due to interlock activated Master unit (only itself)
FAULT (E02) OT!
Fault state due to overtemperature
Each unit
Ex. Display on a unit that has been stopped due to an error occurred in another unit
Display position
of fault state
(Blinking)
LOC
DC
CV
AC
FAULT (E24) OCP !
LOC
DC
CV
AC
DETECT FAULT!
An error detected in
another unit