4 Operation
54
DOEF series
Matsusada Precision
No.
Signal
Description
Direction
Remark
14
FCON
Frequency control
Input
0 to 10V analog signal
ACOM level
15
DCVCON
DC voltage/current control
Input
0 to 10V analog signal
ACOM level
16
NC
Not connected
17
NC
Not connected
18
COM
Common (except analog)
19
OUT_STS
Output status
Output
COM level
20
NC
Not connected
21
STEP_BIT2 Step output bit 2
Output
COM level
22
CVCC_EN
CVCC_SET enabled
Input
COM level
23
ANA_RMT
Analog remote enabled
Input
COM level
24
VCON_EN
Vcon enabled
Input
COM level
25
DCAC_SET setting signal of DC/DCAC mode
Input
COM level
4-5-2 Functional Description
1. LS: Remote switch
The output can be turned on and off with the signal.
In order to use the function, enable it via the operating panel.
2. LD: Interlock
The interlock function is available with the signal.
In order to use the function, enable it via the operating panel.
3. Output status:
The output state, ON or OFF, is output with the signal.
4. Step code:
Step code previously set is output while the sequence is on.
5. Analog remote
Analog remote function is enabled with the signal.
Moreover, each control signal can be enabled or disabled respectively, such as voltage,
current, frequency, and so on.
When a control signal is not enabled, the setting signal will be ignored.
Summary of Contents for DOEF Series
Page 1: ...Instruction Manual F RA 001 3R2 MODEL DOEF series B N 243 9 024 243 9 024 Rev 0 4 ...
Page 15: ...2 External Appearance 7 DOEF series Matsusada Precision 2 3 Dimensions 2 3 1 400W Model ...
Page 16: ...2 External Appearance 8 DOEF series Matsusada Precision 2 3 2 600W Model ...
Page 17: ...2 External Appearance 9 DOEF series Matsusada Precision 2 3 3 1200W Model ...
Page 121: ......
Page 123: ......
Page 124: ......