background image

 

Summary of Contents for EP Series

Page 1: ...Rev 0 2 B N 035 9 114 035 9 114 MODEL EP series Instruction Manual ...

Page 2: ...g of the symbols and observe each item Depending on the product some symbols may not used 禁止 Indicates content that could cause death or serious injury Indicates content that could cause injury or damage to property Indicates danger warning caution Refer to the instruction manual when using the part with this symbol Indicates where high voltage is handled Touching it may cause electric shock and r...

Page 3: ... terminal or GND terminal connect it to the ground If the input terminal of the product is an inlet type connect to the power outlet with the ground using the supplied power cable or a power cable suitable for the area to be used If it is not connected to the ground there is a risk of electric shock and fire which is extremely dangerous About power supply cable If there is a power supply cable att...

Page 4: ...r right hand In case of electric shock when manipulating the product in order to reduce the risk of current flowing through important organs of the body Keep your left hand off from the product and operate with your right hand Do not touch the wiring or load connected to the output terminal or output terminal during operation or immediately after output stop Very high voltage is applied to the ter...

Page 5: ... port and exhaust port are blocked the specified performance of the product cannot be demonstrated and parts are deteriorate which may cause smoke and fire When work such as welding is conducted near the product disconnect all the wires from the product Do not wipe with chemicals thinner etc or wet cloth There is a danger of electric shock electric leakage burnout from chemicals or water entering ...

Page 6: ... 3 1 Outline 4 3 2 Operation method 4 4 Standard functions 4 1 Power supply for preamplifier 5 4 2 Over current protection 5 4 3 Over Voltage Protection 5 5 Option 5 1 External Appearance 6 5 2 connection diagram 6 5 3 Setting Up Master Control Device 7 5 4 Setting of unit number 7 5 5 Command Syntax 8 5 6 Multi command 8 5 7 Character set for commands 9 5 8 Returned data 9 5 9 Command List 10 5 1...

Page 7: ...r supply When unpacked the unit you will please check the following accessories are enclosed with the amplifier main body Accessories AC input cord 1 pc Instruction manual Output cable 1 3 Environmental Requirements Place and use the high voltage amplifier horizontally Never place any object on the high voltage power supply There are air suction and exhaust holes for cooling at upper part and side...

Page 8: ...hibit electrical shock from discharge at load DON T TOUCH the load immediately after turning the output OFF Before touching the load make sure that the Power ON OFF switch of the unit is turned off and output voltage is zero with power supply s voltage monitor or another HV voltmeter How to GROUND 1 5 Troubleshooting In case there is no output voltage 1 Check if the proper input voltage is supplie...

Page 9: ...POWER ON OFF switch HV ON OFF switch Display LCL RMT selector switch option HV output connector Output connector for preamplifier power supply Ground terminal FUSE 3A AC input connector Mode selector switch option Left cursor key Right cursor key Output voltage setting dial ...

Page 10: ...of the unit 2 Connect the attached AC input cord with AC input connector 3 Turn on the POWER Switch The unit gets in stand by mode 4 Turn the output voltage setting dial to adjust the voltage as desired When the HV is OFF value of each digit can be set with cursor key When the HV is ON the output voltage can be set each 1V 5 When the HV is OFF the set voltage on the display When the HV is ON the o...

Page 11: ...fective display shows OVER CURRENT Push the HV switch twice to reset 4 3 Over Voltage Protection O V P This unit has incorporated an over voltage protection and the output is to be cutoff when the voltage reach to approx 105 of maximum rated voltage even if any abnormality occurs When O V P is effective display shows OVER VOLTAGE Push the HV switch twice to reset 4 Standard functions 4 Standard fu...

Page 12: ...ternal Appearance 5 2 connection diagram CO Optical cable connector IN CO Optical cable connector OUT Master control device setting switch CO Series etc 5 Option 5 Option CO Optical cable EP EP POWER MATSUSADA ...

Page 13: ...to the LGob option of CO E32 CO U32 CO G32 CO RG CO HV various power supplies Master control device CO E32 CO U32 CO G32 CO RG CO HV Power supply with LGob option CO OPT2 9 CO OPT2 25 CO OPT4 25 Master control device Setting Switch 8 OFF ON 5 4 Setting of unit number Select the UNIT number setting screen with the MODE selector switch on the front panel and set the UNIT number After changing the UN...

Page 14: ...ter Wrong commands are ignored Specify the UNIT number Use 0 to 31 or AL NOTE The number of characters for a command shall be less than 20 including a delimiter 5 6 Multi command Specifying AL for the UNIT number causes the command to be sent to all units connected Format examples AL VSET 1000 Set the output voltage of all devices to 1000V AL SW1 Enable the output of all units Remarks Refer to the...

Page 15: ...response string being returned with delimiters Example when an STS command is received 1 CO LO If the sent command does not require a response nothing will be returned 0 H 1H 2H 3H 4H 5H 6H 7H 0H NUL DLE SP 0 P p 1H SOH DC1 1 A Q a q 2H STX DC2 2 B R b r 3H ETX DC3 3 C S c s 4H EOT DC4 4 D T d t 5H ENQ NAK 5 E U e u 6H ACK SYN 6 F V f v 7H BEL ETB 7 G W g w 8H BS CAN 8 H X h x 9H HT EM 9 I Y i y A...

Page 16: ...SET Command Set output voltage Operating range 0 to Rated voltage resolution 1 unit V Format examples VSET 1234 Set 1234V Initial value 0 query In response to VSET the set voltage value is returned Remarks Settings out of the operating range are ignored as invalid commands This command supports multi command execution SW Command Sets the output ON OFF Operating range 0 1 0 is OFF 1 is ON Format ex...

Page 17: ... output measurement are ignored When this command is received the RE display on the screen turns off This command supports multi command execution Switching between local control and remote control is also possible with the LCL RMT switch on the front panel VGET Command Output voltage monitor Operating range 0 to Rated voltage resolution 1 unit V Format examples VGET Return examples VGET 1234 outp...

Page 18: ...NIT1 is output status remote control possible CV operations status Status display Output status Control status Error status Output when an error occurs CF Output OFF LO Local control OVP Overvoltage protection CO Output ON RM Remote control OCP Overcurrent protection Remarks Either CF CO and either LO RM is always output SP 20H is output to separate each status 5 Option ...

Page 19: ......

Page 20: ......

Reviews: