3 Connecting
14
HARS series
3-1-2 AC input cable connection (2kW/3kW)
・
Connect the supplied AC input cable with crimp terminals to the input terminal L1, L2, L3,
and .
・
As for the other end of the cable without crimp terminals, attach such as crimp terminals there to
connect to a distribution board with a commertial power supply.
Be sure to electrically ground the product with the AC input terminal. It
is otherwise dangerous for the user.
・
Input voltage: 200-240Vac, 50/60Hz, three-phase
Figure1-2 AC input terminal connection
L1
L3
L2
Attach the cover to the AC input
terminal for use.
Summary of Contents for HARS Series
Page 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Page 10: ......
Page 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Page 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Page 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Page 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Page 92: ......