5-2 Sequence Operation (Pulse/Ramp Sequence)
5-2-1 Overview
The pilse and ramp sequence features of a pulse sequence function that automatically repeats
OUTPUT ON/OFF and a ramp sequence function that allows easy setting of the rising times.
* If the set time is shorter than Tr or Tf of the power supply unit, the output will differ from the setting.
5-2-2 Feature
With the pulse sequence function, the output for a set ON time as the OUTPUT is turned ON and also
stops output for a set OFF time, repeating the specified number of times.
The function can be stopped automatically after the specified number of times, or it can be forced to
stop by turning the OUTPUT OFF.
OUTPUT
ON
OUTPUT
OFF
ON time
OFF time
Start pulse sequence
Stop pulse sequence
1 cycle
Stops after the specified number of times or by turning
the OUTPUT OFF.
5-2-3 Pulse Sequence Setting
OUTPUT ON time
OUTPUT OFF time
Memory OUTPUT
ON time
Pulse sequence ON/OFF button
Repeat count
Function setting screen
Home screen
Pulse sequence screen