7 Operating with Digital Control
58
HARS series
MEASure[:SCALar]:VOLTage[:DC]?
Gets the output voltage value.
Range
0 to (Rated voltage value x 110%)
Unit
“V“
Format
MEAS:VOLT?
Query
Returns the output voltage value in actual value.
MEASure[:SCALar]:CURRent[:DC]?
Gets the output current value.
Range
0 to (Rated value current
x
110%)
Unit
“A”
Format
MEAS:CURR?
Query
Returns the output current value in actual value.
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <n | MINimum | MAXimum>
Sets the output voltage value.
Range
0 to Rated voltage value
Unit
“kV“, “V“, “mV“
Format
example
VOLT 23.45
Initial value
VOLT 0.0
Query
In response to "VOLT?", it returns the set voltage value in actual value.
Remarks
Regarding the range, refer to [7-5 Range for Voltage Setting, Current Setting, and
Power Setting].
[SOURce:]VOLTage:PROTection[:LEVel] <n | MINimum | MAXimum>
Sets the overvoltage protection value.
Range
0 to Rated voltage value x 110%
Unit
“
kV,
“
V
“
,
“
mV
“
Format
example
VOLT:PROT 23.45
Initial value
VOLT:PROT MAX
Query
In response to "VOLT:PROT?", it returns the set overvoltage protection value in actual
value.
Remarks
Regarding the range, refer to [7-9 Range for Voltage Setting and Current Setting].
[SOURce:]VOLTage:LIMit[:UPPer][:IMMediate][:AMPLitude] <n | MINimum | MAXimum>
Sets the voltage upper limit value.
Range
0 to Rated voltage value
Unit
“kV“, “V“, “mV“
Format
example
VOLT:
LIM
23.45
Initial value
VOLT:LIM MAX
Query
In response to VOLT:LIM?, it returns the set voltage upper limit in actual value.
Remarks
Regarding the range, refer to [7-9 Range for Voltage Setting and Current Setting].
Summary of Contents for HARS Series
Page 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Page 10: ......
Page 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Page 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Page 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Page 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Page 92: ......