5 Operation on the Main Unit
28
HARS series
5-1-9 Setting Arc Count Protection
This product has the following two functions that can turn off the output according to the set arc count
value.
1) The output is turned off when more than the set arc count value is detected.
2) The output is turned off when more than the set arc count value is detected within the set time.
Arc count (1)
5-1-9-1
The arc count shows the number of times an arc has occurred. The arc count can be reset to "0" by
touching the arc count reset button.
To enable the function to turn off the output by the arc count, touch the arc count button and set it to
"Enable".
Touching the arc protec count setting value allows you to set the arc protect count value for the arc
you want to turn off the output with the setting change dial.
When the arc count exceeds the arc protect count setting value, the output is turned off.
When the arc count exceeds the arc protect count setting value and the output is stopped, the
following screen is displayed.
Setting screen
Home screen
Arc count
Arc count button
Arc total count
Arc count (1) setting screen
Arc count reset button
Setting value of Arc protect
count
Summary of Contents for HARS Series
Page 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Page 10: ......
Page 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Page 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Page 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Page 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Page 92: ......