4 Advanced Operation
4-5
4-5 Remote Programming
Fluctuation in external voltage or external resistant directly affects output. Ensure
that they are stable.
4-5-1 Setting the Voltage Program with External Voltage
0 to Rating Voltage is controllable with external voltage, 0 to 10V. (3 at SW1 to be ON)
4-5-2 Setting the Voltage Program with External Resistance
0 to Rating Voltage is controllable with external resistor, 0 to 10kΩ.(1 at SW1 to be ON)
CAUTION
TB1
0-10VDC
+
5
1
-S
(Common)
User connection
Power supply unit
Internal circuit
ON
SW1
1
8
0-10kΩ
TB1
6
5
1
-S
(Common)
+
0-1mA
-
Power supply unit
Internal circuit
User connection
ON
SW1
1
8