3 Normal Operation
3-6
③
OVP set in the remote mode
3-5 Blackout Protection
The product is provided with a circuit to prevent accidental restart when the power is recovered
after failure or blackout. No signal is output if the power is recovered while in operation. To
reset, turn the OUTPUT ON/OFF switch to OFF and then back ON.
When the blackout protection function is not to be used, turn SW1-8 ON. In this case, output for
the set value is generated when the power is recovered.
TB1
TTL signal
13
12
11
25
-
+
External relay
5kΩ
100Ω
10
24
23
-S
(Common)
-S
(Common)
Power supply unit
Internal circuit
User connection
SW1
ON
1 2 3 4 5 6 7 8