Table 7-1.
FL
error
code /
display
Symptom
Probable cause
Signal to check
Normal voltage and
waveform / values
Signal
name
Location
PLAY
STOP
E00
Normal
-----
-----
-----
-----
-----
E01
Focus and
tracking
offset
adjustments
has not been
completed in
the specified
time period.
1. IC702’s clock input X1 IN, IC702’s power
supply (V
DD
) or its reset (/RST) is invalid.
2. Any signal MDATA, MCLK, MLD or SENSE
to/from IC601 are invalid.
MDATA IC702-pin 8
0 V
MCLK IC702-pin 7
3.3 V
MLD
IC702-pin 9
3.3 V
/RST
IC702-pin
18
3.3 V
3.3 V
X1 IN
IC702-pin
58
X2 OUT IC702-pin
59
E02,
E03,
E05,
E06,
E07,
E09,
E0A,
E0B,
E0D,
E0E,
E0F
The test disc
does not play
consistently.
1. The disc is scratched or dirty.
2. Focus or tracking servo is malfunctioning
(Check waveforms voltages and circuit
constants).
3. Spindle driver is malfunctioning.
4. Optical pickup is malfunctioning.
FE
IC702-pin
32
1.6 V
TE
IC702-pin
33
1.6 V
FOD
IC702-pin
28
1.6 V
1.6 V
TRD
IC702-pin
27
1.6 V
1.6 V
/RFDET IC702-pin
38
0 V
3.3 V
RF
TJ701
0.9 V
STAT
IC702-pin
17
3.2 V
0 V
FL
error
code /
display
Symptom
Probable cause
Signal to check
Normal voltage and
waveform / values
Signal
name
Location
PLAY
STOP
20
Summary of Contents for SL-PG4
Page 5: ...4 Caution for AC Mains Lead 5 ...
Page 8: ... Follow the Step 1 Step 3 of item 6 1 8 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 16: ...16 ...
Page 17: ...17 ...
Page 27: ...27 ...
Page 28: ...15 Terminal Function of ICs 15 1 IC601 C2BBFE000100 System Control FL Drive 28 ...
Page 41: ...R14 ERDS2FJ103 1 4W 10K 1 41 ...
Page 44: ...18 Loading Unit Parts Location 44 ...
Page 45: ...19 Packaging 45 ...
Page 46: ...F010400000YM MT KH 46 ...