background image

 

      

               

 

Single Phase EV Charger Protection unit 

 

 

 

                                                                

16 | 

P a g e

 

Specifications 

Description 

Electric Vehicle Charger Protection Unit 

Input (Volts) 

Nominal input voltage 230v, 50Hz 

Max Load 

32A  -  All units 

Dimensions 

SP  -  182mm x 169mm x 96 (111)mm 

IP  -  300mm x 200(251)mm x 129(135)mm 

Weight 

Approximately 2.5 kg 

Operating Temp 

-5°C to 40°C 

Storage Temp 

-5°C to 40°C 

Enclosure 

SP  -  Mild Steel Zintec Powder Coated 

IP  -  ABS-HB Flame Retardant plastic 

Power Consumption 

13VA  

Ingress Protection 

SP-EVCP = IP2X       

IP-EVCP = IP65 

Document Revision        

V1.5 Aug 2020 

 

Terminal Capacities

 

Min 

Max 

Torque 

Incoming Terminals cable size &  
tightening torque  

0.5 mm

     6.0mm

1.3Nm 

Incoming RCBO cable size &  
tightening torque 

2.5 mm

     25.0mm

2Nm 

Outgoing Contactor cable size &  
tightening torque 

2.5 mm

  

10,0mm

2

 

2.3Nm 

 

 

WARNING: This equipment is compliant with Class A of EN55032.  

In a residential environment this equipment may cause radio interference. 

 

 

Warranty  

The SP-EVCP units are guaranteed for a period of 3 years from the date of manufacture.  

This warranty is limited to the replacement of faulty components only. 

 

 

 

 

t: 01543 227290 e: info@matt-e.co.uk w: 

www.matt-e.co.uk

 

matt:e Ltd, Unit 5, Common Barn Farm, Tamworth Road, Lichfield WS14 9PX 

Summary of Contents for IP-EVCP-M

Page 1: ...Single Phase Electric Vehicle Charger Protection Units SP EVCP T C SP EVCP R C SP EVCP M C SP EVCP B C IP EVCP T C IP EVCP R C IP EVCP M C Installation Manual V1 5 Aug 2020...

Page 2: ...erating Instructions 14 Status Indicator 15 Specifications 16 Warranty 16 Declaration of Conformity 17 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with t...

Page 3: ...ter April 2020 The units are not intended for any purpose other than that defined within this document WARNINGS Please read and observe the following notices carefully These warnings must be observed...

Page 4: ...e supplied with a split core CT for installing on the main incoming supply cable to the property See page 9 for connection details On detection of fault conditions the electronic circuit disconnects t...

Page 5: ...Single Phase EV Charger Protection unit 5 P a g e...

Page 6: ...Single Phase EV Charger Protection unit 6 P a g e...

Page 7: ...Single Phase EV Charger Protection unit 7 P a g e...

Page 8: ...pply cable from the distribution board directly to the Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PC...

Page 9: ...ly to the MCB Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth connections b...

Page 10: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 11: ...irectly to the MCB RCCD Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth con...

Page 12: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 13: ...Single Phase EV Charger Protection unit 13 P a g e Connection details for CT versions...

Page 14: ...ith a split core CT to allow the unit to monitor whole house load The CT should be clamped around the incoming supply cable directly after the service providers meter It is designed to measure the FUL...

Page 15: ...red flashes 1Hz recovers when current in range Tripped Under voltage 1 red flash over 4 sec period recovers when voltage in range Tripped Over voltage 2 red flashes over 4 sec period recovers when vo...

Page 16: ...Document Revision V1 5 Aug 2020 Terminal Capacities Min Max Torque Incoming Terminals cable size tightening torque 0 5 mm2 6 0mm2 1 3Nm Incoming RCBO cable size tightening torque 2 5 mm2 25 0mm2 2Nm O...

Page 17: ...J Charlton Director Emissions EN60255 1 2010 Emissions standard for Measuring Relays and Protection Equipment EN60255 26 2013 EN55011 2016 A1 2017 Emissions Standard for ISM Equipment EN55032 2012 Em...

Reviews: