Single Phase EV Charger Protection unit 

 

 

 

                                                                

17 | 

P a g e

 

 

EU Declaration of Conformity (DoC) 

Ref : SP-EVCP-01-2020 

We 

Company name: 

 

matt:e Ltd 

Postal address: 

 

Unit 5  Common Barn Farm  Tamworth Road 

City 

 

Lichfield 

Postcode: 

 

WS14 9PX 

Telephone number: 

 

01543-227290 

E-Mail address: 

 

Info@matt-e.co.uk 

Declare that this DoC is issued under the sole responsibility of the manufacturer. 

 

Apparatus model/Product:   SP-EVCP  

Type: 

 

Single Phase Electric Vehicle Charger Protection 

 

Object of the declaration

 

Electric Vehicle Charger 

Protection units 

SP-EVCP-T(C)   SP-EVCP-M(C)   SP-EVCP-R(C)   SP-EVCP-B(C) 

IP-EVCP-T(C)   IP-EVCP-M(C)   IP-EVCP-R(C) 

The object of the declaration described above is in conformity with the relevant Union 

harmonisation legislation: 

Low Voltage Directive (2014/35/EU) 

The following harmonised standards and technical specifications have been applied: 

 

Signed for and on behalf of:  matt:e Ltd 

Place of issue 

 

Date 

 

 

 

Lichfield, England 

 

 17 June 2020   

J Charlton,   Director 

Emissions 
EN60255-1 2010   Emissions standard for Measuring Relays and Protection Equipment 
EN60255-26 2013   

EN55011 2016 + A1:2017    Emissions Standard for ISM Equipment 
EN55032 2012   Emissions Standard for Multimedia Equipment  

 
Immunity 
EN60255-1 2010   Emissions standard for Measuring Relays and Protection Equipment 
EN60255-26 2013     

EN61000-4-2 2009    ESD Requirements 
EN61000-4-3 2006 + A1 + A2    Radiated Susceptibility 
EN61000-4-4 2012    Electrical Fast Transient Burst Requirement 
EN61000-4-5 2006    Surges Requirements 
EN61000-4-6 2009    Conducted Susceptibility 
EN61000-4-11 2004    Voltage Dips and Interruptions 
Following the provisions of EU EMC Directive 2014/30/EU 

 
EN61439-1 & 2 2011    Low-voltage switchgear and controlgear assemblies. 

 

EN60947-4-1    Low-voltage switchgear and control gear 
EN61009-1   Residual current operated circuit-breakers with integral overcurrent 
EN61008-1   Residual current operated circuit-breakers without integral overcurrent 
EN 60898-1:2019 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar 
installations - Part 1: Circuit-breakers for a.c. operation 
 

Summary of Contents for IP-EVCP-M

Page 1: ...Single Phase Electric Vehicle Charger Protection Units SP EVCP T C SP EVCP R C SP EVCP M C SP EVCP B C IP EVCP T C IP EVCP R C IP EVCP M C Installation Manual V1 5 Aug 2020...

Page 2: ...erating Instructions 14 Status Indicator 15 Specifications 16 Warranty 16 Declaration of Conformity 17 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with t...

Page 3: ...ter April 2020 The units are not intended for any purpose other than that defined within this document WARNINGS Please read and observe the following notices carefully These warnings must be observed...

Page 4: ...e supplied with a split core CT for installing on the main incoming supply cable to the property See page 9 for connection details On detection of fault conditions the electronic circuit disconnects t...

Page 5: ...Single Phase EV Charger Protection unit 5 P a g e...

Page 6: ...Single Phase EV Charger Protection unit 6 P a g e...

Page 7: ...Single Phase EV Charger Protection unit 7 P a g e...

Page 8: ...pply cable from the distribution board directly to the Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PC...

Page 9: ...ly to the MCB Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth connections b...

Page 10: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 11: ...irectly to the MCB RCCD Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth con...

Page 12: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 13: ...Single Phase EV Charger Protection unit 13 P a g e Connection details for CT versions...

Page 14: ...ith a split core CT to allow the unit to monitor whole house load The CT should be clamped around the incoming supply cable directly after the service providers meter It is designed to measure the FUL...

Page 15: ...red flashes 1Hz recovers when current in range Tripped Under voltage 1 red flash over 4 sec period recovers when voltage in range Tripped Over voltage 2 red flashes over 4 sec period recovers when vo...

Page 16: ...Document Revision V1 5 Aug 2020 Terminal Capacities Min Max Torque Incoming Terminals cable size tightening torque 0 5 mm2 6 0mm2 1 3Nm Incoming RCBO cable size tightening torque 2 5 mm2 25 0mm2 2Nm O...

Page 17: ...J Charlton Director Emissions EN60255 1 2010 Emissions standard for Measuring Relays and Protection Equipment EN60255 26 2013 EN55011 2016 A1 2017 Emissions Standard for ISM Equipment EN55032 2012 Em...

Reviews: