Single Phase EV Charger Protection unit 

 

 

 

                                                                

3 | 

P a g e

 

Once installed, the unit has a Live Mains Supply (230v or higher) 

within the enclosure. The cover must not be removed until the 

supply to the unit has been isolated or disconnected.

 

Environment 

matt

:

no longer use plastic bags as part of  product packaging.  Wherever possible we utilise reusable 

biodegradable packaging for transportation.  We ask that you support our efforts to reduce un-necessary 

waste and recycle all packaging appropriately. Thank you. 

 

Product Description 

The

 matt

:

e

 Single Phase Electric Vehicle Charger Protection units are designed for use in domestic dwelling 

applications where single phase PME supplies are feeding Electric Vehicle Chargers. They should NOT be 

used on premises with 3 phase supplies 

 

This manual covers the SP-EVCP-T(C), SP-EVCP-R(C), SP-EVCP-M(C), SP-EVCP-B(C), IP-EVCP-T(C), IP-EVCP-R(C), 

& IP-EVCP-M(C) models manufactured after April 2020 

 

The units are not intended for any purpose other than that defined within this document. 

 

WARNINGS 

Please read and observe the following notices carefully. These warnings must be observed when installing 

and operating the Electric Vehicle Charger Protection units.

  

 

All relevant supplies must be isolated or disconnected before commencing any work.  This 

product must be installed by a competent person in accordance with the IET Wiring Regulations, 

BS7671 (18

th

 Edition or later) and any relevant Building Regulations and/or Installation 

Regulations.

 

 

 

 

 

 

Safety Advice 

The unit must be installed in a dry ventilated location; it must never be covered or have restricted 
ventilation.  

The SP-EVCP units are rated for a maximum 32A.  

 

The SP-EVCP-R & IP-EVCP-R models are rated to be connected directly to the supply meter tails 
via suitable connectors.  All other models must be connected via the Consumer Distribution 
Board or ‘Garage Board’ and suitable protective device 

 

 

For any information not contained within this document, please contact our technical support team 
on 01543 227290 or 

info@matt-e.co.uk

Summary of Contents for IP-EVCP-M

Page 1: ...Single Phase Electric Vehicle Charger Protection Units SP EVCP T C SP EVCP R C SP EVCP M C SP EVCP B C IP EVCP T C IP EVCP R C IP EVCP M C Installation Manual V1 5 Aug 2020...

Page 2: ...erating Instructions 14 Status Indicator 15 Specifications 16 Warranty 16 Declaration of Conformity 17 PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with t...

Page 3: ...ter April 2020 The units are not intended for any purpose other than that defined within this document WARNINGS Please read and observe the following notices carefully These warnings must be observed...

Page 4: ...e supplied with a split core CT for installing on the main incoming supply cable to the property See page 9 for connection details On detection of fault conditions the electronic circuit disconnects t...

Page 5: ...Single Phase EV Charger Protection unit 5 P a g e...

Page 6: ...Single Phase EV Charger Protection unit 6 P a g e...

Page 7: ...Single Phase EV Charger Protection unit 7 P a g e...

Page 8: ...pply cable from the distribution board directly to the Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PC...

Page 9: ...ly to the MCB Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth connections b...

Page 10: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 11: ...irectly to the MCB RCCD Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth con...

Page 12: ...directly to the RCBO Incoming Supply terminals Connect the outgoing cable to the contactor L E N terminals If required connect the CT to the 3 pin connector on the PCB Check ALL power and earth conne...

Page 13: ...Single Phase EV Charger Protection unit 13 P a g e Connection details for CT versions...

Page 14: ...ith a split core CT to allow the unit to monitor whole house load The CT should be clamped around the incoming supply cable directly after the service providers meter It is designed to measure the FUL...

Page 15: ...red flashes 1Hz recovers when current in range Tripped Under voltage 1 red flash over 4 sec period recovers when voltage in range Tripped Over voltage 2 red flashes over 4 sec period recovers when vo...

Page 16: ...Document Revision V1 5 Aug 2020 Terminal Capacities Min Max Torque Incoming Terminals cable size tightening torque 0 5 mm2 6 0mm2 1 3Nm Incoming RCBO cable size tightening torque 2 5 mm2 25 0mm2 2Nm O...

Page 17: ...J Charlton Director Emissions EN60255 1 2010 Emissions standard for Measuring Relays and Protection Equipment EN60255 26 2013 EN55011 2016 A1 2017 Emissions Standard for ISM Equipment EN55032 2012 Em...