10 To reduce the risk of personal injury, do not bend blades or any other part of fan when cleaning. Do not insert
foreign objects in between rotating fan blades or in space surrounding entire rotating fan unit. Fan must be turned
off at power at supply source before installation, cleaning or servicing.
11 After making the wire connections in junction box, the wires should be spread apart with the grounded conductor
and the fan-grounding conductor on one side of the junction box and the ungrounded conductor on the other side of
the outlet box. Be sure that all wiring connections are properly insulated from each other and any surrounding metal
parts. For safety and best operating results, we recommend that you have a qualified electrician assemble and
install your fan.
12 To reduce the risk of personal injury, install the supplementary mounting means and use only the hardware
provided with the fan.
READ AND SAVE THESE INSTALLATION INSTRUCTIONS
CONTENTS OF BOX / See Diagram I
---One wall fan assembly. Total fan assembled weight is approximately 8.0 Lbs.
---One canopy (C2) to cover junction box.
---One support pole (D), one mounting plate (H) and one side mount wall junction box.
---One 1/8
th
set screw wrench to tighten 1/8
th
set screws in fan head (B2) and canopy (C2).
---
One proprietary 3 speed wall control.
INSTALLATION DIRECTIONS / See Diagram I
Read these instructions prior to installation.
NOTE: Before installing fan turn off power at service panel and check all visible
screws and bolts for tightness
1. Attach side mount junction box securely to building structure. Use provided hardware.
NOTE: Tighten screws well. Junction box is suitable for support of Michelle Pared wall
mounted fan.
Do not use power tools of any sort in the assembly and mounting of this product.
2. Fully retract the set screws in wall canopy (C2) and carefully push canopy (C2) up the goose
neck/support pole (D) to reveal mounting plate (H). Slide canopy (C2) over the protective
sleeve. Wires (M) are already strung through support pole (D).
3. Pull wires (M) taut through back of mounting plate (H).
4.
NOTE: Connect fan and power source wires at junction box according to national and
local electrical codes such as: NEC, OSHA etc. Re-read recommendations under heading
of "Danger/Warning/Avertissement/Caution/Attention." Note: Green wire is always
grounding wire and should be attached to the junction box for safe operation. If you are
not sure if the outlet box is grounded, contact a licensed electrician for advice. Note:
Do not turn power back on at service panel until step #6 below has been completed.
5. Attach mounting plate (H) to side mount wall junction box using hardware provided. The two
longest screws provided should be use to attach the fan/mounting plate (H) to side mount wall
junction box. Tighten screws well.
6. Push canopy (C2) down support pole (D) until the canopy lays flat against the wall - covering
junction box and mounting plate (H). Tighten set screws (Q) in canopy (C2) well so that it is
secure in its new, permanent position.