Page 19
3.2.4 Line Impulse/Pause Duration
Display:
24 Pulse Pause 01
> 1s 1s
This menu enables the user to set the duration of the impulses on the line. The first
parameter
1s
means that the impulse for the clock will have a period of 1 second.
The second
1s
indicates that after the impulse there will be a minimum 1 second
pause until the next impulse is generated. For a minute impulse clock it will take 2
seconds to make up one minute if the salve clock is not already synchronised.
The line will be pre-programmed to 1s pulse duration and 1s pause duration.
For standard applications the value should be
1s 1s
, for special applications the
duration of the minute pulses/pauses can vary between
1s
,
2s
,
5s
and
10s.
The
pulses/pauses for second impulse slave clocks may vary between
.05s
,
.10s
,
.20s
and
.30s.
With the button
>
>
>
>
you move the cursor to the right and with the buttons
^
^
^
^
and
v
v
v
v
the
impulse/pause durations can be set.
Everything is stored by pressing the button
e
e
e
e
and changes are discarded with the
button
<
<
<
<
or
c.
c.
c.
c.
If anything was changed you have to confirm your entry again by
pressing the
e
e
e
e
button after the query “
Save?
” is displayed. However if the changes
shall be discarded you have to press the
c
c
c
c
button.