Adjust the first notch (0
°
) flap position to be aligned with the aileron trailing edge with the
ailerons centered. Check the flap travel with flap handle at fully retracted (handle down) posi-
tion for negative 7
°
±
1
°
up, and 24
°
±
3
°
down for second notch, 40
°
±
3
°
down for third notch
and 48
°
±
3
°
down for fourth notch
. Adjustment, if needed, may be accomplished by adjusting
turnbuckles located above front seats through headliner. Proper cable tension is 60 lbs.
±
10
lbs.
7. RUDDER:
Set-up for Installation of Rudder Cables:
Lock rudder to vertical stabilizer using a C-Clamp and two (2) padded wood blocks. Es-
tablish the rudder “Neutral Position” by measuring (and holding) a distance of 6” between the
backside of the rudder pedal(s) to the face of the interior firewall. Note: Make sure the interior
(firewall) insulation and (firewall) vinyl covering/upholstery is adequately compressed during
this initial set-up phase. A wooden spacer of the appropriate length (a 2x4 wooden block
works fine) is ideal to hold the given distance during the rudder-rigging process. Install rudder
cables and related-hardware.
Check the rudder travel for
21
°
±
1
°
right and left. Rudder cable tension is controlled by
springs, and the cables should not be slack with the rudder centered. Rudder trim may be ac-
complished by adjusting the tension of the rudder centering springs located behind the rear
bulkhead. Keep springs as short as possible but never less than 4 ½ inches from end coil to
end coil with the rudder centered.
8. ELEVATORS:
Elevator control movements are up 30
°
±
1
°
, down 20
°
±
1
°
. Stops are located on the verti-
cal tail rear spar just inside the inspection plate. Proper cable tension is 25 to 45 lbs.
CAUTION - BEFORE FLIGHT whenever elevator cables are reconnected or new cables in-
stalled: Always check operation of elevators after a cable reconnect by pulling back on the
control wheel and ascertain that the elevators are in the UP position.
9. ELEVATOR TRIM:
Elevator trim tab movement is 12
°
±
2
°
up, 38
°
±
2
°
down. If adjustment is needed, it may
be done at the turnbuckles located just aft of the trim control. Proper cable tension is 15 to 25
lbs.
10. RUDDER TAB: