II Operating instructions: 
Installing batteries and syncing main receiver with sensor: 
1.  Remove  battery  housing  cover  on  the  back  of  the  main  receiver  and  insert  2  x  AAA  batteries. 
Replace housing cover. 
2. Remove mounting bracket from the back of the sensor as illustrated in FIG. 2. Then use a screw driver 
to remove battery housing cover and insert 2 x AAA batteries. Before replacing housing cover, ensure 
CH switch is set to CH 1.  Also select whether you would like Celsius/Fahrenheit by pressing the "°C/°F" 
button.  When  replacing  battery  housing  cover,  ensure  that  the  rubber  seal  is  correctly  in  position  to 
ensure batteries are protected from the weather. 
3. When batteries are in place, the units will automatically detect the current temperature and humidity 
after 3 seconds. If outdoor temperature is not displayed, press "CHANNEL" until the number "1" appears 
below the "OUTDOOR CH" icon. 
Note the current conditions will update every 60 seconds. 
4.  If  you  want  to  reset  current  temperature  information  press  and  hold  the  "CHANNEL"  button  for  2 
seconds. 
 

 

Fig.2 
 
Note: If faint LCD display please replace the battery. 
It is advisable not to exceed 25 meters distance (in open field) between the receiver and the sensor. 
 
 
Common mode: 
1. Press "TIME" for 2 seconds for time setting. 
2. Press "ALARM" to turn on or off alarm after you set the time. 
3. Press "ALARM" for 2 seconds for alarm setting. 
4. Press "UP" for 12HR/24HR format switch. 
5. Press "DOWN" for Celsius/Fahrenheit switch. 
6. Press "CHANNEL" to change channel: CH1 ~ CH2 ~ Ch3. 
7. Press "CHANNEL" for 2 seconds, clear all the channels' present information. 
8. Press "SNZ" to snooze the alarm for 5 minutes when alarm is activated. 
 
Setting the time: 
1. Press "TIME" for 2 seconds, the numbers will flash. 
2. Set hour by pressing the "UP" or "DOWN" buttons. When correct hour appears, press "TIME". Repeat for 
HOUR, 
MINUTE,  YEAR,  MONTH,  DATE,  LANGUAGE,  Please  note  the  flashing  symbols  under  "DAY"  refer  to  the 
language EN 
(ENGLISH), IT(ITALIAN), FR(FRENCH),NE(DUTCH),ES(SPANISH), DA(DANISH) and GE(GERMAN). 
3. Press "TIME" to confirm. 
 
 

Eclipse              1/4 new          1/2 new             3/4 new                    full          3/4 old       1/2 old        1/4 old 

Summary of Contents for 51199

Page 1: ...e meteo Wireless digital thermometer with weather station Termometro digital inalambrico con estacion meteorologica cod 51199 Manuale istruzioni Instruction manual Manual de instrucciones ITALIANO ENG...

Page 2: ...e alcuni errori si verificano al chiuso o in ambiente con aria condizionata 2 Temperatura interna intervallo da 0 a 50 C 3 Umidit interna intervallo di rilevamento dal 20 al 95 4 Temperatura esterna g...

Page 3: ...mere CHANNEL fino a quando il numero 1 appare sotto l icona OUTDOOR CH Nota che le condizioni attuali si aggiorneranno ogni 60 secondi 4 Se si desidera ripristinare le informazioni sulla temperatura c...

Page 4: ...ile premere il tasto SNZ che posticipa l allarme per 5 minuti o puoi disattivare l allarme premendo una volta il tasto ALARM L allarme rimarr attivato vedere il simbolo della campana a meno che non si...

Page 5: ...ed environment 2 Indoor temperature Range of 0 octo 50 C 3 Indoor humidity Range of detection 20 to 95 4 Outdoor temperature Range of 20 acto 60 C 5 Outdoor humidity Range of detection 20 to 95 6 Week...

Page 6: ...econds 4 If you want to reset current temperature information press and hold the CHANNEL button for 2 seconds Fig 2 Note If faint LCD display please replace the battery It is advisable not to exceed 2...

Page 7: ...e alarm by pressing the ALARM button once The alarm will stay activated see bell symbol unless you press the ALARM button again to turn off the alarm bell symbol disappears Information on disposal for...

Page 8: ...pron stico puede ser bajo condiciones ventiladas normales existe alg n error cuando est bajo techo o con aire acondicionado medio ambiente 2 Temperatura interior Rango de 0 octo 50 C 3 Humedad interio...

Page 9: ...eratura exterior no se visualiza presione CHANNEL hasta que aparezca el n mero 1 debajo del cono OUTDOOR CH Tenga en cuenta que las condiciones actuales se actualizar n cada 60 segundos 4 Si desea res...

Page 10: ...esionar el bot n SNZ para posponga la alarma durante 5 minutos o puede apagar la alarma presionando el bot n ALARMA una vez La alarma se mantendr activado ver s mbolo de campana a menos que presione e...

Reviews: