Setting up
26
Switch off the machine!
Danger of injury due to unintentional starting of the machine !
Only use needles from the system intended for the machine, see Chapter
3
Specifi cations.
MA 2545
Set needle bar at top position and
loosen screw
1.
1.
Push the needle fully in (the long
needle groove must face to the left)
Tighten screw
MA 2546
Set needle bar at top position and loosen
screw
2.
Push the needle fully in (the long groove
of the left needle must face to the right
and that of the right needle to the left).
Tighten screw
2
again.
8
Preparation
All regulations and instructions in this Instruction Manual are to be observed!
Special attention is to be paid to the safety regulations !
All preparation work is only to be carried out by appropriately trained personnel.
Before all preparation work, the machine is to be separated from the electricity
supply by removing the plug from the mains or switching off the On/Off switch!
8
.01
Inserting the needle
Fig. 8 - 01
Fig. 8 - 01a
1
2